Siemens SINAMICS G List Manual page 130

Table of Contents

Advertisement

Parameters
Parameter list
Values:
0:
1:
100:
Dependency:
Refer to: p0010
Note:
A factory setting run can only be started if p0010 was first set to 30 (parameter reset).
At the end of the calculations, p0970 is automatically set to 0.
p0971
Save drive object parameters / Save drv_obj
All objects
Can be changed: U, T
Data type: Unsigned16
P-Group: Displays, signals
Min
0
Description:
Saves the parameters of the particular drive object in the non-volatile memory (CompactFlash Card).
Values:
0:
1:
Dependency:
Refer to: p0977
Cautiont:
The control unit power supply may only be powered-down after data has been saved (i.e. after data save has been
started, wait until the parameter again has the value 0).
Note:
Starting from the particular drive object, the following parameters are saved:
CU3xx: Device-specific parameters and PROFIBUS device parameters.
Other objects: Parameters of the actual object and PROFIBUS device parameters.
r0975[0...10]
Drive object identification /
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Displays the identification of the drive object.
Index:
[0] = Company (Siemens = 42)
[1] = Drive object type
[2] = Firmware version
[3] = Firmware date (year)
[4] = Firmware date (day/month)
[5] = PROFIdrive drive object, type class
[6] = PROFIdrive drive object, sub-type Class 1
[7] = Reserved
[8] = Reserved
[9] = Reserved
[10] = Firmware patch/hot fix
Note:
Example:
r0975[0] = 42 --> SIEMENS
r0975[1] = 11 --> SERVO drive object type
r0975[2] = 102 --> first part, firmware version V01.02 (second part, refer to index 10)
r0975[3] = 2003 --> year 2003
r0975[4] = 1401 --> 14th of January
r0975[5] = 1 --> PROFIdrive drive object, type class
r0975[6] = 9 --> PROFIdrive drive object sub-type class 1
r0975[7] = 0 (reserved)
r0975[8] = 0 (reserved)
r0975[9] = 0 (reserved)
r0975[10] = 600 --> second part, firmware version (complete version: V01.02.06.00)
1-130
not active
Starts a parameter reset
Starts a BICO interconnection reset
not active
Save drive object
Data set: -
Units group: -
Max
1
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents