Parameters
Parameter list
p9908
Topology comparison, comparison stage of a component / Topo_cmpr 1 comp
CU
Can be changed: C1
Data type: Integer16
P-Group: Topology
Min
0
Description:
Sets the type of comparison of a component in the target topology with the actual topology.
The comparison is started by setting the required value.
Values:
0:
1:
2:
3:
99:
Dependency:
Refer to: p9907
Note:
The electronic rating plate comprises the following data:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
- Manufacturer (e.g. SIEMENS)
- hardware version (e.g. "A")
- Serial No. (e.g. "T-P30050495")
When comparing the topology, the following data is compared in the target and actual topologies:
p9908 = 0: Component type, Order No., Hardware version, Manufacturer, Serial No.
p9908 = 1: Component type, Order No.
p9908 = 2: Component type
p9908 = 3: Component class (e.g. sensor module or motor module)
p9909
Topology comparison, component replacement / Topo_cmpr replace
CU
Can be changed: C1
Data type: Unsigned8
P-Group: Topology
Min
0
Description:
For p9908 = 1, the serial number and the hardware version of the new replaced component is automatically trans-
ferred from the actual topology into the target topology and then saved in a non-volatile fashion.
For the components that have been replaced, the electronic type plate must match as far as the following data is
concerned:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
Dependency:
Refer to: p9904, p9905
Note:
Components must be replaced before POWER ON in order that the changes in the target topology are automati-
cally saved in a non-volatile fashion.
p9915
DRIVE-CLiQ data transfer error, shutdown threshold, master / DLQ fault master
CU
Can be changed: C1
Data type: Unsigned32
P-Group: Topology
Min
0000 hex
Description:
Only for internal Siemens service.
1-358
High: Compares the complete electronic rating plate
Average: Compares the component type and the Order number
Low: Compares the component type
Minimum: Compares the component class
Topology has different comparison stages
Data set: -
Units group: -
Max
99
Data set: -
Units group: -
Max
1
Data set: -
Units group: -
Max
0007 07FF hex
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
1
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
0007 02FF hex