Siemens SINAMICS G List Manual page 140

Table of Contents

Advertisement

Parameters
Parameter list
p1030[0...n]
Motorized potentiometer, configuration / Mop configuration
VECTOR
Can be changed: U, T
Data type: Unsigned16
P-Group: Control
Min
0000 bin
Description:
Sets the configuration for the motorized potentiometer.
Bit field:
Bit
Signal name
00
Data save active
01
Ramp-function generator active
02
Initial rounding-off active
Note:
Re bit 01:
0: Without ramp-function generator in the automatic mode (ramp-up/ramp-down time = 0).
1: With ramp-function generator in the automatic mode.
Re bit 02:
0: Without initial rounding-off
1: With initial rounding-off. The selected ramp-up/down time is correspondingly exceeded. The initial rounding-off is
a sensitive way of specifying small changes (progressive reaction when keys are pressed).
p1035[0...n]
BI: Motorized potentiometer, setpoint, raise / Mop raise
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source to increase the setpoint for the motorized potentiometer
Dependency:
Refer to: p1036
p1036[0...n]
BI: Motorized potentiometer, lower setpoint / Mop lower
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source to reduce the setpoint for the motorized potentiometer.
Dependency:
Refer to: p1035
p1037[0...n]
Motorized potentiometer, maximum speed / Mop n_max
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
-210000.000 [1/min]
Description:
Sets the maximum speed/velocity for the motorized potentiometer.
Note:
This parameter is automatically pre-assigned in the commissioning phase.
The setpoint output from the motorized potentiometer is limited to this value.
1-140
Data set: DDS
Units group: -
Max
0111 bin
0 signal
No
No
No
Data set: CDS
Units group: -
Max
-
Data set: CDS
Units group: -
Max
-
Data set: DDS
Units group: SPEED_ROT
Max
210000.000 [1/min]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 3020
Unit selection: -
Factory setting
0110 bin
1 signal
FP
Yes
-
Yes
-
Yes
-
Access level: 3
Function diagram: 2442,
2505
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 2442,
2505
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: 3020
Unit selection: -
Factory setting
0.000 [1/min]