Siemens SINAMICS G List Manual page 111

Table of Contents

Advertisement

Dependency:
Refer to: p0771, r0772, r0774, p0776, p0777, p0778, p0779, p0780, p0783, p0784, r0786
r0774[0...2]
Test sockets output voltage / TestSkts U_output
CU
Can be changed: -
Data type: Floating Point
P-Group: Terminals
Min
- [V]
Description:
Displays the actual output voltage for the test sockets.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Refer to: p0771, r0772, p0776, p0777, p0778, p0779, p0780, p0783, p0784, r0786
p0776[0...2]
Test socket mode / Test skt mode
CU
Can be changed: U, T
Data type: Integer16
P-Group: Terminals
Min
96
Description:
Sets the mode for the test sockets.
Values:
96:
97:
98:
99:
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Refer to: p0771, r0772, r0774, p0777, p0778, p0779, p0780, p0783, p0784, r0786, p0788, p0789, r0790
p0777[0...2]
Test socket characteristic value x1 / Test skt char x1
CU
Can be changed: U, T
Data type: Floating Point
P-Group: Terminals
Min
-100000.00 [%]
Description:
The normalization characteristic for the test sockets is defined using two points. This parameter specifies the x
coordinate (percentage) of the first point on the characteristic.
Index:
[0] = T0
[1] = T1
[2] = T2
Dependency:
Can only be set when p0776 = 99.
Refer to: p0778, p0779, p0780, r0786
Note:
The value 0.00 % corresponds to 2.49 V.
p0778[0...2]
Test socket characteristic value y1 / Test skt char y1
CU
Can be changed: U, T
Data type: Floating Point
P-Group: Terminals
Min
0.00 [V]
Description:
The normalization characteristic for the test sockets is defined using two points. This parameter specifies the y
coordinate (output voltage) of the first point on the characteristic.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Physical address (32-bit integer signal, unsigned)
Physical address (32-bit integer signal)
Physical address (32-bit floating-point signal)
BICO signal
Data set: -
Units group: VOLTAGE_DC
Max
- [V]
Data set: -
Units group: -
Max
99
Data set: -
Units group: PERCENT
Max
100000.00 [%]
Data set: -
Units group: VOLTAGE_DC
Max
4.98 [V]
Parameters
Parameter list
Access level: 2
Function diagram: 8134
Unit selection: -
Factory setting
- [V]
Access level: 4
Function diagram: 8134
Unit selection: -
Factory setting
99
Access level: 2
Function diagram: 8134
Unit selection: -
Factory setting
0.00 [%]
Access level: 2
Function diagram: 8134
Unit selection: -
Factory setting
2.49 [V]