Siemens SINAMICS G List Manual page 153

Table of Contents

Advertisement

p1145[0...n]
Ramp-function generator tracking intensity. / RFG track intens
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
0.0
Description:
Sets the ramp-function generator tracking.
The output value of the ramp-function generator is tracked (corrected) corresponding to the maximum possible
drive acceleration. The reference value is the deviation at the speed/velocity controller input that is necessary to
ensure that the motor runs-up at the torque/force limit.
Recommenda-
p1145 = 0.0:
tion:
This value de-activates the ramp-function generator tracking.
p1145 = 0.0 ... 1.0:
Generally, these values are not practical. They cause the motor to accelerate below its torque limit. The lower the
selected value, the greater the margin between the controller and torque limit at run-up.
p1145 > 1.0:
The greater the value, the higher the permissible deviation between the speed setpoint and speed actual value.
Note:
In the V/f mode, the ramp-function generator tracking is not active.
For SERVO with V/f operation, the following applies:
The complete ramp-function generator is not active, i.e. ramp-up and ramp-down time = 0.
p1148[0...n]
Ramp-function generator, tolerance for ramp-up and ramp-down active / RFG tol
HL/RL act
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
0.00 [1/min]
Description:
Sets the tolerance value for the status of the ramp-function generator (ramp-up active, ramp-down active).
If the input of the ramp-function generator does not change in comparison to the output by more than the entered
tolerance time, then the status bits "ramp-up active" and "ramp-down active" are not influenced.
Dependency:
Refer to: r1199
r1150
CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Setpoints
Min
- [1/min]
Description:
Displays the setpoint at the output of the ramp-function generator.
p1152
BI: Setpoint 2 enable / Setpt 2 enable
VECTOR (Extended
Can be changed: T
brk)
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source for "setpoint 2 enable".
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: -
Max
50.0
Data set: DDS
Units group: SPEED_ROT
Max
1000.00 [1/min]
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: -
Units group: -
Max
-
Parameters
Parameter list
Access level: 3
Function diagram: 3080
Unit selection: -
Factory setting
1.3
Access level: 3
Function diagram: 3060,
3070
Unit selection: -
Factory setting
19.80 [1/min]
Access level: 3
Function diagram: 1550,
3060, 3070, 3080
Unit selection: -
Factory setting
- [1/min]
Access level: 3
Function diagram: 2711
Unit selection: -
Factory setting
899.15
1-153