Parameters
Parameter list
p4102[0...1]
TM31 temperature evaluation fault/alarm threshold / TM31 temp thresh
TM31
Can be changed: T
Data type: Integer16
P-Group: -
Min
-48 [°C]
Description:
Sets the fault/alarm threshold for the temperature evaluation of terminal module 31 (TM31).
Temperature actual value > p4102[0] --> alarm A35211 is output.
Temperature actual value > p4102[1] --> fault F35207 is output.
Index:
[0] = Alarm threshold
[1] = Fault threshold
Dependency:
Refer to: r4104
Warning!
Fault F35207 only causes the drive to be shut down if there is at least one BICO interconnection between the drive
and TM31.
Note:
The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
A value > 250 °C deactivates the alarm or fault.
r4104
BO: TM31 temperature evaluation, status / TM31 temp status
TM31
Can be changed: -
Data type: Unsigned16
P-Group: Terminals
Min
-
Description:
Displays the status for the temperature evaluation of terminal module 31 (TM31).
This displays as to whether the temperature actual value has exceeded the fault/alarm threshold.
Bit field:
Bit
Signal name
00
Temperature alarm threshold exceeded
01
Temperature fault threshold exceeded
Dependency:
Refer to: p4102
r4105
CO: TM31 temperature evaluation, actual value / TM31 temp actValue
TM31
Can be changed: -
Data type: Floating Point
P-Group: Terminals
Min
- [°C]
Description:
Displays the actual temperature value of the temperature evaluation of terminal module 31 (TM31).
Dependency:
For sensor type PTC (p4100 = 1), the following applies:
- below the nominal response temperature, r4105 = -50°C.
- above the nominal response temperature, r4105 = 199.9 °C.
For sensor type KTY84-130 (p4100 = 2), the following applies:
- the displayed value corresponds to the temperature actual value.
Refer to: p4100
Note:
The temperature sensor is connected at terminals X522.7(+) and X522.8(-).
For an invalid temperature actual value, (e.g. a short-circuit at the sensor input), r4105 = -300 °C is displayed.
1-310
Data set: -
Units group: TEMPERATURE
Max
251 [°C]
Data set: -
Units group: -
Max
-
0 signal
No
No
Data set: -
Units group: TEMPERATURE
Max
- [°C]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 1
Function diagram: 9576
Unit selection: -
Factory setting
[0] 100 [°C]
[1] 120 [°C]
Access level: 1
Function diagram: 1840,
9576
Unit selection: -
Factory setting
-
1 signal
FP
Yes
-
Yes
-
Access level: 1
Function diagram: 1840,
9576
Unit selection: -
Factory setting
- [°C]