Siemens SINAMICS G List Manual page 645

Table of Contents

Advertisement

Cause:
The temperature measured using the temperature sensing of the TM (r4105) has exceeded the threshold value to
initiate this alarm (p4102[0]).
Alarm value (r2124, decimal):
The hundred thousands and ten thousands location specifies the component number of the TMxx where the fault
occurred.
Remedy:
Allow the temperature sensor to cool down.
Reaction upon F:
NONE
Acknowledge
IMMEDIATELY (power on)
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
F35220 (N, A)
TM: Frequency limit reached for signal output
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY (power on)
Cause:
The signals output from the terminal module 41 (TM41) for tracks A/B have reached the limit frequency. The output
signals are no longer in synchronism with the specified setpoint.
Remedy:
- enter a lower speed setpoint (p1155).
- reduce the encoder pulse number (p0408).
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
Reaction upon A:
NONE
Acknowledge
NONE
upon A:
F35221 (N, A)
TM: Setpoint - actual value deviation, outside the tolerance range
Reaction:
OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY (power on)
Cause:
The deviation between the setpoint and the output signals (track A/B) exceeds the tolerance of +/-3 %.
Remedy:
- reduce the basic clock cycle (p0110, p0111).
- replace the module.
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
Reaction upon A:
NONE
Acknowledge
NONE
upon A:
A35222 (F, N)
TM: Encoder pulse number not permissible
Reaction:
NONE
Acknowledge:
NONE
Cause:
The encoder pulse number entered does not match the permissible pulse number from a hardware perspective.
Fault value (r0949, decimal):
1: Encoder pulse number is too high.
2: Encoder pulse number is too low.
4: Encoder pulse number is less than the zero mark offset (p4426)
Remedy:
Enter the encoder pulse number in the permissible range (p0408).
Reaction upon F:
OFF1 (NONE, OFF2, OFF3)
Acknowledge
IMMEDIATELY (power on)
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N: