Siemens SINAMICS G List Manual page 249

Table of Contents

Advertisement

p2098[0...1]
Invert connector-binector converter bit-serial / CI_BO conv inv
All objects
Can be changed: U, T
Data type: Unsigned16
P-Group: Communication
Min
0000 bin
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of CI: p2099[0] are influenced.
Using p2098[1], the signals of CI: p2099[1] are influenced.
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
Dependency:
Refer to: r2094, r2095, p2099
Note:
Bit x = 1: Inverts the appropriate binector output.
Bit x = 0: No inversion.
p2099[0...1]
CI: PROFIBUS PZD selection receive bit-serial / Select CO_BO conv
All objects
Can be changed: U, T
Data type: Unsigned32
P-Group: Communication
Min
-
Description:
Selects a PROFIBUS PZD receive word for bit-serial interconnection.
Dependency:
Refer to: r2094, r2095
Note:
p2099 together with r2094 and r2095 forms two connector-binector converters:
Connector input p2099[0] to binector outputs in r2094
Connector input p2099[1] to binector outputs in r2094
p2100[0...19]
Setting the fault number for fault response / F_no F response
All objects
Can be changed: U, T
Data type: Unsigned16
P-Group: Messages
Min
0
Description:
Selects the faults for which the fault response should be changed
Dependency:
The fault is selected and the required response is set under the same index.
Refer to: p2101
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
1111 1111 1111 1111 bin
0 signal
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Not inverted
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
65535
Parameters
Parameter list
Access level: 3
Function diagram: 2460
Unit selection: -
Factory setting
0000 bin
1 signal
FP
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Inverted
-
Access level: 3
Function diagram: 2460
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 1750,
8075
Unit selection: -
Factory setting
0
1-249