Parameters
Parameter list
r7101[0...99]
Parallel circuit configuration, ring buffer data set number / Ring buffer Ds_No.
VECTOR (Parallel)
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power modules connected in parallel (motor module,
active line infeed, voltage sensing module).
p7101 < 100:
Displays the power module data set number (Power Data Set, PDS).
p7101 >= 100:
Displays the voltage sensing module data set number (VSMDS)
Dependency:
Refer to: r7100, r7102, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7102[0...99]
Parallel circuit configuration, ring buffer fault/alarm received / F/A received
VECTOR (Parallel)
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power modules connected in parallel (motor module,
active line infeed, voltage sensing module).
Displays the relative system runtime when the fault or alarm occurred.
Dependency:
Refer to: r7100, r7101, r7103
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
r7103[0...99]
Parallel circuit configuration, ring buffer fault/alarm gone / F/A gone
VECTOR (Parallel)
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Min
-
Description:
Ring buffer for faults and alarms that have occurred from power modules connected in parallel (motor module,
active line infeed, voltage sensing module).
Displays the relative system runtime when the fault or alarm was withdrawn.
Dependency:
Refer to: r7100, r7101, r7102
Note:
The last fault case that occurred is documented in index 0.
The parameter is reset to 0 at POWER ON.
1-320
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-