p0108[0...15]
Drive object, function module / DO function module
CU_G
Can be changed: C1
Data type: Unsigned32
P-Group: -
Min
0000 bin
Description:
The function module of an existing drive object is entered into each index.
Bit field:
Bit
Signal name
30
COMMUNICATION BOARD
Note:
A "function module" is a functional expansion of a drive object that can be activated when commissioning.
r0108
Drive object, function module / DO function module
VECTOR
Can be changed: -
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Displays the activated function module for the particular drive object.
Bit field:
Bit
Signal name
02
Closed-loop speed/torque control
14
Extended brake control
15
Parallel circuit configuration
16
Technology controller
17
Extended messages/monitoring
Note:
A "function module" is a functional expansion of a drive object that can be activated when commissioning.
p0110[0...2]
DRIVE-CLiQ basis sampling times / DLQ basis clock
CU
Can be changed: C1
Data type: Floating Point
P-Group: Control
Min
31.25 [µs]
Description:
Setting the basic clock cycles.
The basis clock cycle of the device (e.g. drive unit) is identical with the current controller clock cycle of a DRIVE-
CLiQ communications line. All current controller clock cycles of the same communications line (e.g. current control-
ler clock cycles of the drives) must be identical with the selected basis clock cycle.
The basis clock cycle for individual drives is selected in p0111.
Index:
[0] = Bas. clock cycle 0
[1] = Bas. clock cycle 1
[2] = Bas. clock cycle 2
Note:
The basis clock cycle can be changed in steps of 1.25 µs.
The values of the basic clock cycles are aligned to the number of drives.
The factory settings should be kept.
After parameters have been changed, they should be saved and a POWER ON carried-out.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
1111 1111 1111 1111 1111 1111
1111 1111 bin
0 signal
Not activated
Data set: -
Units group: -
Max
-
0 signal
Not activated
Not activated
Not activated
Not activated
Not activated
Data set: -
Units group: TIME_M6
Max
10000.00 [µs]
Parameters
Parameter list
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
0000 bin
1 signal
FP
Activated
-
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
-
1 signal
FP
Activated
-
Activated
-
Activated
-
Activated
-
Activated
-
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
[0] 125.00 [µs]
[1] 250.00 [µs]
[2] 250.00 [µs]