Siemens SINAMICS G List Manual page 128

Table of Contents

Advertisement

Parameters
Parameter list
r0963
PROFIBUS baud rate / PROFIBUS baud rate
CU
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Values:
0:
1:
2:
3:
4:
6:
7:
8:
9:
10:
11:
255:
r0964[0...6]
Device identification / Device ident.
CU
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Displays the device identification.
Index:
[0] = Company (Siemens = 42)
[1] = Device type
[2] = Firmware version
[3] = Firmware date (year)
[4] = Firmware date (day/month)
[5] = Number of drive objects
[6] = Firmware patch/hot fix
Note:
Example:
r0964[0] = 42 --> SIEMENS
r0964[1] = 5000 --> SINAMICS S CU320
r0964[1] = 5200 --> SINAMICS G CU320
r0964[2] = 102 --> first part of the firmware version V01.02 (second part, refer under index 6)
r0964[3] = 2003 --> year 2003
r0964[4] = 1401 --> 14th of January
r0964[5] = 4 --> 4 drive objects
r0964[6] = 600 --> second part, firmware version (complete version: V01.02.06.00)
r0965
PROFIBUS profile number / PB profile number
CU
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Displays the PROFIBUS profile number and profile version. Constant value = 0303 hex.
Byte 1: Profile number = 03 hex = PROFIdrive profile 3
Byte 2: Profile version = 03 hex = Version 3
1-128
9.6 kbit/s
19.2 kbit/s
93.75 kbit/s
187.5 kbit/s
500 kbit/s
1.5 Mbit/s
3 Mbit/s
6 Mbit/s
12 Mbit/s
31.25 kbit/s
45.45 kbit/s
Unknown
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-