Siemens SINAMICS G List Manual page 318

Table of Contents

Advertisement

Parameters
Parameter list
r7031
Parallel circuit configuration, maximum deviation DC link voltage / Vdc max deviation
VECTOR (Parallel)
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [V]
Description:
Displays the maximum absolute deviation of the measured DC link voltage from the average value.
The deviation of the individual voltages from the average value is displayed in r7030.
Dependency:
Refer to: r7030
Refer to: A05053
p7040[0...n]
Parallel circuit configuration, valve lockout time correction, phase U positive / Comp
t_interl Upos
VECTOR (Parallel)
Can be changed: U, T
Data type: Floating Point
P-Group: Modulation
Min
0.00 [µs]
Description:
Using this correction time, the valve lockout time in phase U (p1828) is compensated for a positive phase current
for the particular motor module. This therefore takes into account a spread in the valve lockout times of motor mod-
ules in a parallel circuit configuration.
Dependency:
Refer to: p1828
p7041[0...n]
Parallel circuit configuration, valve lockout time correction, phase U negative / Comp
t_interl Uneg
VECTOR (Parallel)
Can be changed: U, T
Data type: Floating Point
P-Group: Modulation
Min
0.00 [µs]
Description:
Using this correction time, the valve lockout time in phase U (p1828) is compensated for a negative phase current
for the particular motor module. This therefore takes into account a spread in the valve lockout times of motor mod-
ules in a parallel circuit configuration.
Dependency:
Refer to: p1828
p7042[0...n]
Parallel circuit configuration, valve lockout time correction, phase V positive / Comp
t_interl Vpos
VECTOR (Parallel)
Can be changed: U, T
Data type: Floating Point
P-Group: Modulation
Min
0.00 [µs]
Description:
Using this correction time, the valve lockout time in phase V (p1829) is compensated for a positive phase current for
the particular motor module. This therefore takes into account a spread in the valve lockout times of motor modules
in a parallel circuit configuration.
Dependency:
Refer to: p1829
1-318
Data set: -
Units group: VOLTAGE_DC
Max
- [V]
Data set: PDS
Units group: TIME_M6
Max
1000000.00 [µs]
Data set: PDS
Units group: TIME_M6
Max
1000000.00 [µs]
Data set: PDS
Units group: TIME_M6
Max
1000000.00 [µs]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [V]
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
0.00 [µs]
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
0.00 [µs]
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
0.00 [µs]