Parameters
Parameter list
Note:
The existing parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here. In
a long list, index 99 contains the parameter number at which position the list continues.
This list completely comprises the following parameters:
r0980[0...99], r0981[0...99] ... r0989[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0989[0...99]
List of existing parameters 10 / List avail par 10
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Min
-
Description:
Displays the parameters that exist for this drive.
Dependency:
Refer to: r0980, r0981
Note:
The existing parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here.
This list completely comprises the following parameters:
r0980[0...99], r0981[0...99] ... r0989[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0990[0...99]
List of modified parameters 1 / List changed par 1
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Min
-
Description:
Displays those parameters with a value other than the factory setting for this drive.
Dependency:
Refer to: r0991, r0999
Note:
Modified parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here. In a
long list, index 99 contains the parameter number at which position the list continues.
This list completely comprises the following parameters:
r0990[0...99], r0991[0...99] ... r0999[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
r0991[0...99]
List of modified parameters 2 / List changed par 2
All objects
Can be changed: -
Data type: Unsigned16
P-Group: -
Min
-
Description:
Displays those parameters with a value other than the factory setting for this drive.
Dependency:
Refer to: r0990, r0999
Note:
Modified parameters are displayed in indices 0 to 98. If an index contains the value 0, then the list ends here. In a
long list, index 99 contains the parameter number at which position the list continues.
This list completely comprises the following parameters:
r0990[0...99], r0991[0...99] ... r0999[0...99]
The parameters in this list are not displayed in the expert list of the commissioning software. However, they can be
read from a higher-level control system (e.g. PROFIBUS master).
1-134
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents