Note:
CU: Control unit
SBC: Safe brake control
SH: Safe standstill
SI: Safety Integrated
r9772
CO/BO: SI status (control unit) / SI status CU
VECTOR
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Min
-
Description:
Displays the Safety Integrated status on the control unit.
Bit field:
Bit
Signal name
00
SH selected on control unit
01
SH active on the control unit
04
SBC requested
09
STOP A cannot be acknowledged, active
10
STOP A active
15
STOP F active
Dependency:
Refer to: r9872
r9773
CO/BO: SI status (control unit + motor module) / SI status CU + MM
VECTOR
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Min
-
Description:
Displays the Safety Integrated status on the drive (control unit + motor module).
Bit field:
Bit
Signal name
00
SH in the drive selected
01
SH in the drive active
31
Shutdown paths must be tested
Note:
This status is formed from the AND operation of the relevant status of the two monitoring channels.
r9774
CO/BO: SI status (safe standstill group) / SI status group SH
VECTOR
Can be changed: -
Data type: Unsigned32
P-Group: Safety Integrated
Min
-
Description:
Displays the status for Safety Integrated of the group to which this drive belongs.
This signal is an AND logic operation of the individual status signals of the drives included in this group.
Bit field:
Bit
Signal name
00
SH selected in group
01
SH active in group
31
Shutdown paths of the group must be tested No
Dependency:
Refer to: p9620, r9773
Note:
A group is formed by appropriately grouping the terminals for "safe standstill".
The status of a group of n drives is, for drives 1 to n - 1 displayed with a delay of one monitoring clock cycle; this is
a system-related effect.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
-
0 signal
No
No
No
No
No
No
Data set: -
Units group: -
Max
-
0 signal
No
No
No
Data set: -
Units group: -
Max
-
0 signal
No
No
Parameters
Parameter list
Access level: 2
Function diagram: 2804
Unit selection: -
Factory setting
-
1 signal
FP
Yes
2810
Yes
2810
Yes
2814
Yes
2802
Yes
2802
Yes
2802
Access level: 2
Function diagram: 2804
Unit selection: -
Factory setting
-
1 signal
FP
Yes
2810
Yes
2810
Yes
2810
Access level: 2
Function diagram: 2804
Unit selection: -
Factory setting
-
1 signal
FP
Yes
2804
Yes
2804
Yes
2804
1-351