Siemens SINAMICS G List Manual page 38

Table of Contents

Advertisement

Parameters
Parameter list
Dependency:
Refer to: r0024
Note:
The output frequency is available smoothed (r0024) and unsmoothed (r0066).
r0067
Maximum drive output current / Drv I_output max
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Aeff]
Description:
Displays the maximum output current of the motor module.
Dependency:
The maximum output current is determined by the parameterized current limit and the motor and converter thermal
protection.
Refer to: p0290, p0640
r0068
CO: Absolute current actual value / I_act abs.val.
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Aeff]
Description:
Displays actual absolute current.
Dependency:
Refer to: r0027
Note:
The calculated RMS value is only applicable for sinusoidal currents.
For DC current, a value is displayed that is too low by sqrt(2).
Absolute current value = sqrt(Iq^2 + Id^2)
The absolute current actual value is available smoothed (r0027) and unsmoothed (r0068).
r0069[0...6]
Phase current, actual value / I_Phase act value
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [A]
Description:
Displays the measured actual phase currents as peak value.
Index:
[0] = Phase U
[1] = Phase V
[2] = Phase W
[3] = Phase U offset
[4] = Phase V offset
[5] = Phase W offset
[6] = Total U, V, W
Note:
In indices 3 ... 5, the offset currents of the 3 phases, which are added to correct the phase currents, are displayed.
The sum of the 3 corrected phase currents is displayed in index 6.
1-38
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: -
Units group: CURRENT_AC_PP
Max
- [A]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 5722,
6300, 6640, 6724
Factory setting
- [Aeff]
Access level: 3
Function diagram: 5730,
6714, 8014, 8950
Factory setting
- [Aeff]
Access level: 3
Function diagram: 1630,
5730, 6714, 6731, 8950
Unit selection: -
Factory setting
- [A]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents