p9905
Device specialization / Device specializ.
CU
Can be changed: C1
Data type: Unsigned16
P-Group: Topology
Min
0
Description:
With p9905 = 1, the serial numbers and the hardware versions of all of the components are transferred from the
actual topology into the target topology and a new comparison is started..
For the device specialization, the components of the target topology may only differ from those of the actual topol-
ogy by the serial numbers.
Note:
p9905 is automatically set to 0 at the end of the operation.
In order to permanently accept the data, it is necessary to save in a non-volatile fashion (p0977).
p9906
Topology comparison, comparison stage of all components / Topo_cmpr tot comp
CU
Can be changed: C1
Data type: Integer16
P-Group: Topology
Min
0
Description:
Sets the type of comparison between the actual topology and target topology.
The comparison is started by setting the required value.
Values:
0:
1:
2:
3:
99:
Note:
The electronic rating plate comprises the following data:
- component type (e.g. "SMC20")
- Order No. (e.g. "6SL3055-0AA0-5BA0")
- Manufacturer (e.g. SIEMENS)
- hardware version (e.g. "A")
- Serial No. (e.g. "T-P30050495")
When comparing the topology, the following data is compared in the target and actual topologies:
p9906 = 0: Component type, Order No., Hardware version, Manufacturer, Serial No.
p9906 = 1: Component type, Order No.
p9906 = 2: Component type
p9906 = 3: Component class (e.g. sensor module or motor module)
p9907
Topology comparison, comparison stage of the component number / Topo_cmpr
comp_no
CU
Can be changed: C1
Data type: Unsigned8
P-Group: Topology
Min
0
Description:
Enters the number of the component where the setting of how the actual topology should be compared to the target
topology should be changed.
Dependency:
Refer to: p9908
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
High: Compares the complete electronic rating plate
Average: Compares the component type and the Order number
Low: Compares the component type
Minimum: Compares the component class
Topology has different comparison stages
Data set: -
Units group: -
Max
1
Data set: -
Units group: -
Max
99
Data set: -
Units group: -
Max
199
Parameters
Parameter list
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0