Product: SINAMICS G, Version: V02.20.28.00, Label: ARM_M0475_11, Language: en
r0002
Control module, operating display / CU op_display
CU
Can be changed: -
Data type: Integer16
P-Group: -
Min
-
Description:
Operating display for the control board.
Values:
0:
10:
20:
31:
33:
34:
35:
70:
80:
99:
r0002
Drive operating display / Drv op_display
VECTOR
Can be changed: -
Data type: Integer16
P-Group: -
Min
-
Description:
Operating display for the drive.
The value provides information about the actual operating state and the conditions necessary to reach the next
operating state.
The higher the numerical value, the greater the number of conditions that still have to be fulfilled in order to achieve
the "Run" operating state.
Values:
0:
10:
11:
12:
13:
14:
15:
16:
17:
18:
the fault
21:
22:
23:
31:
41:
42:
43:
44:
45:
46:
Dependency:
Refer to: r0046
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
[00] Operation
[10] Ready
[20] Wait for run-up
[31] Commissioning software download active
[33] Remove topology error / acknowledge
[34] Exit the commissioning mode
[35] Carry-out first commissioning
[70] Initialization
[80] Reset active
[99] Internal software error
[00] Operation - everything enabled
[10] Operation - set "enable setpoint" signal to "1" (p1142)
[11] Operation - set "enable speed controller" signal to "1" (p0856)
[12] Operation - RFG frozen, set "RFG start" signal to "1" (p1141)
[13] Operation - set "enable ramp-function generator" signal to "1" (p1140)
[14] Operation - wait for the brake opening time (p1216, vector magn_time p0346)
[15] Operation - open brake (p1215)
[16] Operation - Withdraw braking with OFF1 using "ON/OFF1" signal to "1"
[17] Operation - braking with OFF3 can only be interrupted with OFF2
[18] Operation - a fault has occurred and the drive brakes - remove the cause of the fault and acknowledge
[21] Ready - set the "enable operation" signal to "1" (p0852)
[22] Ready - de-magnetization running (vector de-magn_time p0347)
[23] Ready - set "infeed operation" signal to "1" (p0864)
[31] Ready to power-up - set the "ON/OFF1" signal with 0/1 edge (p0840)
[41] Power-on inhibit - set the "ON/OFF1" signal with 0/1 edge (p0840)
[42] Power-on inhibit - set "OC/OFF2" signal to "1" (p0844, p0845)
[43] Power-on inhibit - set "OC/OFF3" signal to "1" (p0848, p0849)
[44] Power-on inhibit - connect 24 V to terminal EP (hardware)
[45] Power-on inhibit - remove the cause of the fault, acknowledge the fault
[46] Power-on inhibit - exit the commissioning mode (p0009, p0010)
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Parameters
Parameter list
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
-