Siemens SINAMICS G List Manual page 283

Table of Contents

Advertisement

p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Free function blocks
Min
-100000.00 [Nm]
Description:
Sets a fixed value for torque / force.
Dependency:
Refer to: p2900, p2901
Note:
The value can, for example, be used to interconnect a supplementary torque.
p3900
Completion of quick commissioning / End quick_commis.
VECTOR
Can be changed: C2
Data type: Integer16
P-Group: Displays, signals
Min
0
Description:
Exits the quick commissioning (p0010 = 1) with automatic calculation of all of the parameters that depend on the
entries made during the quick commissioning.
p3900 = 1 initially includes a parameter reset (factory setting, the same as p0970 = 1) for all parameters of the drive
object; however, without overwriting the entries made during the quick commissioning.
The interconnections of PROFIBUS PZD telegram selection (p0922) and the interconnections via p0700, p1000
and p1500 are re-established and all of the dependent motor, open-loop and control-loop control parameters are
calculated (corresponding to p0340 = 1).
p3900 = 2 includes the restoration of the interconnections of PROFIBUS PZD telegram selection (p0922) and the
interconnections via p0700, p100 and p1500 and the calculations corresponding to p0340 = 1.
p3900 = 3 only includes the calculations associated with the motor, open-loop and closed-loop control parameters
corresponding to p0340 = 1.
Values:
0:
1:
2:
3:
Note:
When the calculations have been completed, p3900 and p0010 are automatically reset to a value of 0.
When calculating motor, open-loop and closed-loop control parameters (such as for p0340 = 1) parameters associ-
ated with a selected Siemens list motor are not overwritten.
p3902[0...n]
Power module EEPROM Vdc calibration / PM EEPROM Vdc_cal
VECTOR
Can be changed: C1, C2, T
Data type: Unsigned32
P-Group: All groups
Min
0
Description:
Calibration factor for the DC link voltage measurement.
Caution!
Incorrect use of the calibration can have a negative impact on the closed-loop control.
Note:
The parameter only has an effect for chassis-type power modules.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
No quick parameterization
Quick parameterization after parameter reset
Quick parameterization (only) for BICO and motor parameters
Quick parameterization for motor parameters (only)
Data set: DDS
Units group: TORQUE
Max
100000.00 [Nm]
Data set: -
Units group: -
Max
3
Data set: PDS
Units group: -
Max
4294967295
Parameters
Parameter list
Access level: 3
Function diagram: 3030
Unit selection: -
Factory setting
0.00 [Nm]
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0
1-283

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents