Siemens SINAMICS G List Manual page 270

Table of Contents

Advertisement

Parameters
Parameter list
Bit field:
Bit
Signal name
01
|n_act| <= speed threshold value 2
02
|n_act| > speed threshold value 2
03
n_act >= 0
06
n_act > n_max
07
Speed setp - act val deviation in tolerance
t_off
Note:
Re bit 01, 02:
The speed threshold value 2 is set in p2155.
r2198
CO/BO: Status word monitoring 2 / ZSW monitor 2
VECTOR
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the second status word for monitoring functions.
Bit field:
Bit
Signal name
04
|n_set| < p2161
05
n_set > 0
06
Motor locked
07
Motor stalled
10
Torque setpoint < torque threshold value 1
11
Load monitoring signals an alarm
12
Load monitoring signals a fault condition
Note:
Re bit 10:
The torque threshold value 1 is set in p2174.
Re bit 07:
For servo drives, bit 07 is not used and is always inactive.
r2199
CO/BO: Status word monitoring 3 / ZSW monitor 3
VECTOR
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the third status word for monitoring functions.
Bit field:
Bit
Signal name
00
|n_act| < speed threshold value 3
01
f or n comparison value reached or
exceeded
04
Speed setp - act val deviation in tolerance
t_on
05
Ramp-up/ramp-down completed
11
Torque utilization < torque threshold value 2 No
Note:
Re bit 00:
The speed threshold value 3 is set in p2161.
Re bit 01:
The comparison value is set in p2141.
Re bit 11:
The torque threshold value 2 is set in p2194.
1-270
0 signal
No
No
No
No
No
Data set: -
Units group: -
Max
-
0 signal
No
No
No
No
No
No
No
Data set: -
Units group: -
Max
-
0 signal
No
No
No
No
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
1 signal
FP
Yes
8010
Yes
8010
Yes
8010
Yes
8010
Yes
8010
Access level: 2
Function diagram: 1530,
2536
Unit selection: -
Factory setting
-
1 signal
FP
Yes
8010
Yes
8010
Yes
8012
Yes
8012
Yes
8012
Yes
8013
Yes
8013
Access level: 2
Function diagram: 1530,
2536
Unit selection: -
Factory setting
-
1 signal
FP
Yes
8010
Yes
8010
Yes
8010
Yes
8010
Yes
8012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents