p7829
Activate firmware download / Act. FW_download
CU
Can be changed: U, T
Data type: Integer16
P-Group: -
Min
0
Description:
Setting this parameter to 1 activates a firmware download for the DRIVE CLiQ component indicated in p7828:1:
1: Activate download
0: Download successfully completed
>1: Error code
011: DRIVE-CLiQ component has detected a checksum error.
015: The selected DRIVE-CLiQ component did not accept the contents of the firmware file.
101: After several communication attempts, not response from the DRIVE-CLiQ component.
140: Firmware file for the DRIVE-CLiQ component is not available on the CompactFlash Card.
156: Component with the specified component number is not available.
Additional values:
Only for internal Siemens troubleshooting.
Dependency:
Component number of the DRIVE-CLiQ component for which the firmware is to be downloaded.
Refer to: p7828
Note:
p7829 is automatically reset to 0 after the firmware has been successfully downloaded.
The new firmware only becomes active at the next system run-up.
p7830[0...15]
Diagnostics telegram selection / Diag telegram
CU
Can be changed: T
Data type: Integer16
P-Group: -
Min
0
Description:
Selects a telegram whose contents should be shown in p7831 ... p7836.
Values:
0:
1:
2:
3:
Index:
[0] =
[1] =
[2] =
[3] =
[4] =
[5] =
[6] =
[7] =
[8] =
[9] =
[10] =
[11] =
[12] =
[13] =
[14] =
[15] =
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Reserved
First cyclic receive telegram, sensor 1
First cyclic receive telegram, sensor 2
First cyclic receive telegram, sensor 3
Data set: -
Units group: -
Max
999
Data set: -
Units group: -
Max
3
Parameters
Parameter list
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
0