Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0333[0...n]
Rated motor torque / Mot M_rated
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
- [Nm]
Description:
Displays the motor rated torque/force.
Note:
For induction and reluctance motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
r0334[0...n]
Motor-torque constant, actual / Mot kT act
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
- [Nm/A]
Description:
Displays the torque/force constant of the synchronous motor used.
Dependency:
Refer to: p0316
Note:
This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 = p0316 is displayed. if p0316 = 0, r0334 is calculated from p0305 and
p0312.
p0335[0...n]
Motor cooling type / Motor cooling type
VECTOR
Can be changed: C2, T
Data type: Integer16
P-Group: Motor
Min
0
Description:
Sets the motor cooling system used.
Values:
0:
1:
2:
4:
5:
6:
Note:
The parameter influences the thermal 3-mass motor model.
1LA1 and 1LA8 motors are characterized by the fact that they have an internal rotor fan.
The parameter is automatically preset for motors from the motor list (p0301).
r0336[0...n]
Rated motor frequency (actual) / Mot f_rated act
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Motor
Min
- [Hz]
Description:
Displays the rated frequency of the motor.
For p0310 > 0, this value is displayed.
Dependency:
Refer to: p0311, p0314
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Non-ventilated
Forced-ventilated
Water cooling
Non-ventilated and internal fan
Forced-ventilated and internal fan
Water cooling and internal fan
Data set: MDS
Units group: TORQUE
Max
- [Nm]
Data set: MDS
Units group:
TORQUE_PER_CURR
Max
- [Nm/A]
Data set: MDS
Units group: -
Max
6
Data set: MDS
Units group: FREQUENCY
Max
- [Hz]
Parameters
Parameter list
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [Nm]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [Nm/A]
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [Hz]
1-71