p1663[0...n]
Current setpoint filter 2 denominator natural frequency / I_set_filt 2 fn_n
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.5 [Hz]
Description:
Sets the denominator natural frequency for current setpoint filter 2 (PT2, general filter).
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
p1664[0...n]
Current setpoint filter 2 denominator damping / I_set_filt 2 D_n
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.001
Description:
Sets the denominator damping for current setpoint filter 2.
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
p1665[0...n]
Current setpoint filter 2 numerator natural frequency / I_set_filt 2 fn_z
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.5 [Hz]
Description:
Sets the numerator natural frequency for current setpoint filter 2 (general filter).
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
p1666[0...n]
Current setpoint filter 2 numerator damping / I_set_filt 2 D_z
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.000
Description:
Sets the numerator damping for current setpoint filter 2.
Dependency:
The current setpoint filters are parameterized with p1656 to p1676.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: FREQUENCY
Max
16000.0 [Hz]
Data set: DDS
Units group: -
Max
10.000
Data set: DDS
Units group: FREQUENCY
Max
16000.0 [Hz]
Data set: DDS
Units group: -
Max
10.000
Parameters
Parameter list
Access level: 3
Function diagram: 5710,
6710
Unit selection: -
Factory setting
1999.0 [Hz]
Access level: 3
Function diagram: 5710,
6710
Unit selection: -
Factory setting
0.700
Access level: 3
Function diagram: 5710,
6710
Unit selection: -
Factory setting
1999.0 [Hz]
Access level: 3
Function diagram: 5710,
6710
Unit selection: -
Factory setting
0.700