Note:
The purpose of slip compensation is to maintain a constant motor speed regardless of the applied load. The fact
that the motor speed decreases with increasing load is a typical characteristic of induction motors.
For synchronous motors, this effect does not occur and the parameter has no effect in this case.
p1336[0...n]
Slip compensation limit value / Slip comp lim val
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: V/f control
Min
0.00 [%]
Description:
Sets the limit value for slip compensation in [%] referred to r0330 (motor rated slip).
r1337
Actual slip compensation / Slip comp act.val.
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: V/f control
Min
- [%]
Description:
Displays the actual compensated slip [%] referred to r0330 (rated motor slip).
Dependency:
p1335 > 0 %: Slip compensation active.
Refer to: p1335
p1338[0...n]
V/f mode resonance damping gain / Uf Res_damp gain
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: V/f control
Min
0.00
Description:
Sets the controller gain for resonance damping for V/f control.
Dependency:
Refer to: p1300, p1339
Note:
The resonance damping function dampens active current oscillations that frequency occur under no-load condi-
tions.
The resonance damping is active in a range of approximately 5 ... 70 % of the rated motor frequency (p0310).
p1339[0...n]
V/f mode resonance damping filter time constant / Uf Res_damp T
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: V/f control
Min
1.00 [ms]
Description:
Sets the filter time constant of the controller for resonance damping with V/f control.
Dependency:
Refer to: p1300, p1338
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: PERCENT
Max
600.00 [%]
Data set: -
Units group: PERCENT
Max
- [%]
Data set: DDS
Units group: -
Max
100.00
Data set: DDS
Units group: TIME_M3
Max
1000.00 [ms]
Parameters
Parameter list
Access level: 2
Function diagram: 6310
Unit selection: -
Factory setting
250.00 [%]
Access level: 3
Function diagram: 6310
Unit selection: -
Factory setting
- [%]
Access level: 3
Function diagram: 1690,
6310
Unit selection: -
Factory setting
0.00
Access level: 3
Function diagram: 6310
Unit selection: -
Factory setting
20.00 [ms]