Cause:
When evaluating the temperature sensor, an error occurred.
Alarm value (r2124, decimal):
1: Wire breakage or sensor not connected (KTY: R > 1630 Ohm).
2: Measured resistance too low (PTC: R < 30 Ohm, KTY: R < 340 Ohm).
Remedy:
- check that the sensor is connected correctly.
- replace sensor.
Reaction upon F:
NONE
Acknowledge
IMMEDIATELY (power on)
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
A35999 (F, N)
TM: Unknown alarm
Reaction:
NONE
Acknowledge:
NONE
Cause:
An alarm has occurred on the terminal module that cannot be interpreted by the control unit firmware.
This can occur if the firmware on the terminal module is more recent than the firmware on the control unit.
Alarm value (r2124, decimal):
Alarm number.
If required, the significance of this new alarm can be referred to in a more recent description of the control unit.
Remedy:
- replace the firmware on the terminal module by an older firmware version (r0158).
- upgrade the firmware on the control unit (r0018).
Reaction upon F:
NONE (DCBRAKE, OFF1, OFF2, OFF3, STOP1, STOP2)
Acknowledge
IMMEDIATELY (power on)
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
F40000
Fault on another drive object
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
A fault has occurred for a drive object with an object number greater than 62.
Fault value (r0949, decimal):
Drive object number with fault.
Remedy:
Evaluate the fault buffer of the object specified in the fault value.
F40002
Fault on drive object with object number 2
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
A fault has occurred for the drive object with this object number.
Fault value (r0949, decimal):
First fault that has occurred for this drive object.
Remedy:
Evaluate the fault buffer of the specified object.
F40003
Fault on drive object with object number 3
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
A fault has occurred for the drive object with this object number.
Fault value (r0949, decimal):
First fault that has occurred for this drive object.
Remedy:
Evaluate the fault buffer of the specified object.
F40004
Fault on drive object with object number 4
Reaction:
NONE
Acknowledge:
IMMEDIATELY