Siemens SINAMICS G List Manual page 198

Table of Contents

Advertisement

Parameters
Parameter list
r1538
CO: Upper effective torque limit / M_max upper eff
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Control
Min
- [Nm]
Description:
Displays the actually effective upper torque/force limit.
Note:
The effective upper torque limit is reduced with respect to the upper torque limit p1520, if the current limit p0640 is
reduced or the rated magnetizing current of the induction motor p0320 is increased.
For vector drives (refer to p0107), this is possibly the case for rotating measurements (refer to p1960).
The torque limit P1520 can be re-calculated using p0340 = 1, 3 or 5.
r1539
CO: Lower effective torque limit / M_max lower eff
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Control
Min
- [Nm]
Description:
Displays the actually effective lower torque/force limit.
Note:
The effective lower torque limit is reduced with respect to the selected lower torque limit p1521 if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
For vector drives (refer to p0107), this is possibly the case for rotating measurements (refer to p1960).
The torque limit P1520 can be re-calculated using p0340 = 1, 3 or 5.
p1540[0...n]
CI: Torque limit upper scaling / M_max upper scal
VECTOR (n/M)
Can be changed: T
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Sets the signal source for the scaling of the upper torque limiting to limit the speed controller output.
p1541[0...n]
CI: Torque limit lower scaling / M_max lower scal
VECTOR (n/M)
Can be changed: T
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Sets the signal source for the scaling of the lower torque limiting to limit the speed controller output.
1-198
Data set: -
Units group: TORQUE
Max
- [Nm]
Data set: -
Units group: TORQUE
Max
- [Nm]
Data set: CDS
Units group: -
Max
-
Data set: CDS
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 2
Function diagram: 1590,
1610, 1750, 5610, 5650, 5714,
6040, 6060, 6640, 8012
Unit selection: -
Factory setting
- [Nm]
Access level: 2
Function diagram: 1590,
1610, 1750, 5610, 5650, 5714,
6040, 6060, 6640, 8012
Unit selection: -
Factory setting
- [Nm]
Access level: 3
Function diagram: 6060
Unit selection: -
Factory setting
1
Access level: 3
Function diagram: 6060
Unit selection: -
Factory setting
1