r0062
CO: Speed setpoint after the filter / n_set after filter
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [1/min]
Description:
Displays the actual speed/velocity setpoint after the setpoint filters.
r0063
CO: Actual speed, smoothed / n_act smooth
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [1/min]
Description:
Displays the actual smoothed speed/velocity actual value for the speed/velocity control.
Dependency:
Refer to: r0021
Note:
This value is calculated in sensorless operation and for V/f control.
For closed-loop vector control, the value in r0063 can be smoothed again and displayed in r1445.
The value displayed in r0021 is the smoothed value of r0063.
r0064
CO: Speed controller system deviation / n_ctrl system dev
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [1/min]
Description:
Displays the actual control difference of the speed/velocity controller.
Note:
In the servo control mode with active reference model, the system deviation to the P component of the speed/veloc-
ity controller is displayed.
r0065
Slip frequency / f_Slip
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Hz]
Description:
Displays the slip frequency for induction motors.
r0066
CO: Drive output frequency / Drv f_output
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Hz]
Description:
Displays the motor module output frequency.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: -
Units group: FREQUENCY
Max
- [Hz]
Data set: -
Units group: FREQUENCY
Max
- [Hz]
Parameters
Parameter list
Access level: 3
Function diagram: 1590,
1750, 5020, 5030, 5210, 6030
Unit selection: -
Factory setting
- [1/min]
Access level: 3
Function diagram: 1580,
1590, 4710, 6010, 6040, 8010
Unit selection: -
Factory setting
- [1/min]
Access level: 3
Function diagram: 5040,
6040
Unit selection: -
Factory setting
- [1/min]
Access level: 3
Function diagram: 6310,
6730
Unit selection: -
Factory setting
- [Hz]
Access level: 3
Function diagram: 1690,
5300, 5730, 6310, 6730, 6731
Unit selection: -
Factory setting
- [Hz]
1-37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents