p1134[0...n]
p1135[0...n]
p1136[0...n]
p1137[0...n]
p1145[0...n]
p1148[0...n]
p1189[0...n]
p1200[0...n]
p1202[0...n]
p1203[0...n]
p1240[0...n]
p1243[0...n]
p1245[0...n]
p1247[0...n]
p1250[0...n]
p1251[0...n]
p1252[0...n]
p1255[0...n]
p1256[0...n]
p1257[0...n]
p1280[0...n]
p1283[0...n]
p1285[0...n]
p1287[0...n]
p1290[0...n]
p1291[0...n]
p1292[0...n]
p1293[0...n]
p1295[0...n]
p1296[0...n]
p1297[0...n]
p1300[0...n]
p1310[0...n]
p1311[0...n]
p1320[0...n]
p1321[0...n]
p1322[0...n]
p1323[0...n]
p1324[0...n]
p1325[0...n]
p1326[0...n]
p1327[0...n]
p1335[0...n]
p1336[0...n]
p1338[0...n]
p1339[0...n]
p1340[0...n]
p1341[0...n]
p1345[0...n]
p1346[0...n]
p1350[0...n]
p1400[0...n]
p1401[0...n]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Ramp-function generator rounding-off type / RFG round-off type
OFF3 ramp-down time / RFG OFF3 t_ramp-dn
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
OFF3 final rounding-off time / RFG OFF3 t_end_del
Ramp-function generator tracking intensity. / RFG track intens
Ramp-function generator, tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
Speed setpoint configuration / n_ctrl config
FlyRest oper mode / FlyRest oper mode
FlyRest srch curr / FlyRest srch curr
Flying restart search rate factor / FlyRst v_Srch Fact
Vdc controller configuration / Vdc_ctrl config
Vdc_max controller dynamic factor / Vdc_max dyn_factor
Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
Vdc_min controller dynamic factor (kinetic buffering) / Vdc_min dyn_factor
Vdc controller proportional gain / Vdc_ctrl Kp
Vdc controller integral action time / Vdc_ctrl Tn
Vdc controller derivative-action time / Vdc_ctrl t_deriv.
Vdc_min controller time threshold / Vdc_min t_thresh
Vdc_min controller response (kinetic buffering) / Vdc_min response
Vdc_min controller speed threshold / Vdc_min n_thresh
Vdc controller configuration (V/f) / Vdc_ctrl config
Vdc_max controller dynamic factor (V/f) / Vdc_max dyn_factor
Vdc_min controller switch-in level (kinetic buffering) (V/f) / Vdc_min on_level
Vdc_min controller dynamic factor (kinetic buffering) (V/f) / Vdc_min dyn_factor
Vdc controller proportional gain (V/f) / Vdc_ctrl Kp
Vdc controller integral action time (V/f) / Vdc_ctrl Tn
Vdc controller derivative-action time (V/f) / Vdc_ctrl t_deriv.
Vdc controller output limit (V/f) / Vdc_ctrl outp_lim
Vdc_min controller time threshold (V/f) / Vdc_min t_thresh
Vdc_min controller response (kinetic buffering) (V/f / Vdc_min response
Vdc_min controller speed threshold (V/f) / Vdc_min n_thresh
Open-loop/closed-loop control operating mode / Control mode
Voltage boost permanent / U_boost perm
Voltage boost at acceleration / U_boost accelerate
V/f control programmable characteristic frequency 1 / Uf char f1
V/f control programmable characteristic voltage 1 / Uf char U1
V/f control programmable characteristic frequency 2 / Uf char f2
V/f control programmable characteristic voltage 2 / Uf char U2
V/f control programmable characteristic frequency 3 / Uf char f3
V/f control programmable characteristic voltage 3 / Uf char U3
V/f control programmable characteristic frequency 4 / Uf char f4
V/f control programmable characteristic voltage 4 / Uf char U4
Slip compensation, scaling / Slip comp scal
Slip compensation limit value / Slip comp lim val
V/f mode resonance damping gain / Uf Res_damp gain
V/f mode resonance damping filter time constant / Uf Res_damp T
I_max frequency controller proportional gain / I_max_ctrl Kp
I_max frequency controller integral action time / I_max_ctrl Tn
I_max voltage controller proportional gain / I_max_U_ctrl Kp
I_max voltage controller integral action time / I_max_U_ctrl Tn
Soft starting / Soft starting
Speed control configuration / n_ctrl config
Flux control configuration / F_ctrl config