Siemens SINAMICS G List Manual page 246

Table of Contents

Advertisement

Parameters
Parameter list
Index:
[0] = Status word 1
[1] = Status word 2
[2] = Free status word 3
[3] = Free status word 4
Dependency:
Refer to: p2051, p2080, p2081, p2082, p2083
Note:
r2089 together with p2080 to p2083 forms four binector-connector converters.
r2090
BO: PROFIBUS PZD1 receive bit-serial / PB PZD1 recv bitw
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Binector output for bit-serial interconnection of PZD1 (normally control word 1) received from the PROFIBUS mas-
ter.
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
r2091
BO: PROFIBUS PZD2 received bit-serial / PB PZD2 recv bitw
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Binector output for bit-serial interconnection of PZD2 received from the PROFIBUS master.
Bit field:
Bit
Signal name
00
Bit 0
01
Bit 1
02
Bit 2
03
Bit 3
04
Bit 4
05
Bit 5
06
Bit 6
07
Bit 7
08
Bit 8
09
Bit 9
10
Bit 10
11
Bit 11
12
Bit 12
13
Bit 13
14
Bit 14
15
Bit 15
1-246
Data set: -
Units group: -
Max
-
0 signal
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Data set: -
Units group: -
Max
-
0 signal
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 2460
Unit selection: -
Factory setting
-
1 signal
FP
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
Access level: 3
Function diagram: 2460
Unit selection: -
Factory setting
-
1 signal
FP
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-

Hide quick links: