[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
[8] = PZD 9 +10
[9] = PZD 10 + 11
[10] = PZD 11 + 12
[11] = PZD 12 + 13
[12] = PZD 13 + 14
[13] = PZD 14 + 15
[14] = PZD 15 + 16
Dependency:
Refer to: p8851
r8874[0...15]
COMM BOARD PZD diagnostics bus address receive / CB diag addr recv
VECTOR
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Bus address of sender from which the PZD is received.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
Note:
Value range:
0 - 125: Bus address of the sender
255: Not occupied
r8875[0...15]
COMM BOARD PZD diagnostics telegram offset receive / CB diag offs recv
VECTOR
Can be changed: -
Data type: Unsigned16
P-Group: Communication
Min
-
Description:
Byte offset of the PZD in the COMM BOARD receive telegram.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Parameters
Parameter list
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
-
1-343