Siemens SINAMICS G List Manual page 214

Table of Contents

Advertisement

Parameters
Parameter list
r1779
Motor model absolute flux / MotMod abs flux
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Control
Min
- [%]
Description:
Displays the absolute value of the flux of the motor model.
p1780[0...n]
Motor model configuration adaptation / MotMod config adap
VECTOR (n/M)
Can be changed: U, T
Data type: Unsigned8
P-Group: Control
Min
0000 bin
Description:
Sets the configuration for the adaptation circuit of the motor model:
Induction motor: Rs, Lh and offset compensation.
Permanent-magnet synchronous motor: kT
Bit field:
Bit
Signal name
01
Select motor model IM Rs adaptation
02
Select motor model IM Lh adaptation
03
Select motor model PESM KT adaptation
04
Select motor model, offset adaptation
p1781[0...n]
Motor model IM Rs adaptation integral action time / MotMod Rs Tn
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
10 [ms]
Description:
Sets the integral action time for the Rs adaptation of the motor model of the induction motor.
r1782
Motor model IM Rs adaptation correction value / MotMod Rs corr
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Control
Min
- [Ohm]
Description:
Displays the correction value for the Rs adaptation of the motor model for the induction motor.
p1783[0...n]
Motor model IM Rs adaptation Kp / MotMod Rs Kp
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.000
Description:
Sets the proportional gain for the Rs adaptation of the motor model of the induction motor.
1-214
Data set: -
Units group: PERCENT
Max
- [%]
Data set: DDS
Units group: -
Max
0001 1110 bin
0 signal
No
No
No
No
Data set: DDS
Units group: TIME_M3
Max
10000 [ms]
Data set: -
Units group: RESISTANCE
Max
- [Ohm]
Data set: DDS
Units group: -
Max
1.000
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [%]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0001 1100 bin
1 signal
FP
Yes
-
Yes
-
Yes
-
Yes
-
Access level: 3
Function diagram: -
Unit selection: p0528
Factory setting
100 [ms]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [Ohm]
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0.100