p0811
BI: Command data set selection CDS bit 1 / CDS select., bit 1
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source to select the command data set bit 1 (CDS bit 1).
Dependency:
Refer to: r0050, p0810, p0812, p0813, r0836
Note:
Command data sets are selected using the binector inputs p0810, p0811, p0812 and p0813.
For a command data set, selected using the binector inputs, is displayed in r0836.
The currently effective command data set is displayed in r0050.
A command data set can be copied using p0809.
p0812
BI: Command data set selection CDS bit 2 / CDS select., bit 2
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source to select the command data set bit 2 (CDS bit 2).
Dependency:
Refer to: r0050, p0810, p0811, p0813, r0836
Note:
Command data sets are selected using the binector inputs p0810, p0811, p0812 and p0813.
For a command data set, selected using the binector inputs, is displayed in r0836.
The currently effective command data set is displayed in r0050.
A command data set can be copied using p0809.
p0813
BI: Command data set selection CDS bit 3 / CDS select., bit 3
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Commands
Min
-
Description:
Sets the signal source to select the command data set bit 3 (CDS bit 3).
Dependency:
Refer to: r0050, p0810, p0811, p0812, r0836
Note:
Command data sets are selected using the binector inputs p0810, p0811, p0812 and p0813.
For a command data set, selected using the binector inputs, is displayed in r0836.
The currently effective command data set is displayed in r0050.
A command data set can be copied using p0809.
p0819[0...2]
Copy drive data set DDS / Copy DDS
VECTOR
Can be changed: C2
Data type: Unsigned8
P-Group: Data sets
Min
0
Description:
Copies a drive data set (DDS) into another.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
31
Parameters
Parameter list
Access level: 3
Function diagram: 2578
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 2578
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 2578
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: 8565
Unit selection: -
Factory setting
[0] 0
[1] 0
[2] 0
1-117