p9650
SI tolerance time SGE changeover (control unit) / SI tol SGE_chgovCU
VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Min
0.00 [ms]
Description:
Sets the tolerance time to change over the safety-related input signals (SGE) on the control unit.
A SGE changeover is not simultaneously effective due to the different runtimes in the two monitoring channels.
After an SGE switchover, dynamic data is not subject to a crosswise data comparison during this tolerance time.
Dependency:
Refer to: p9850
Note:
For a crosswise data comparison between p9650 and p9850, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is internally rounded-off to an integer multiple of the monitoring clock cycle.
SGE: Safety-related input signal (e.g. SH terminals)
p9658
SI transition time STOP F to STOP A (control unit) / SI STOP F to A CU
VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Min
0.00 [ms]
Description:
Sets the transition period from STOP F to STOP A on the control unit.
Dependency:
Refer to: r9795, p9858
Refer to: F01611
Note:
For a crosswise data comparison between p9658 and p9858, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is internally rounded-off to an integer multiple of the monitoring clock cycle.
STOP F: Defect in a monitoring channel (error in the crosswise data comparison)
STOP A: Pulse cancellation via the safety shutdown path
p9659
SI timer for the forced checking procedure / SI TimerFrcdCkProc
VECTOR
Can be changed: C2
Data type: Floating Point
P-Group: Safety Integrated
Min
0.00 [h]
Description:
Sets the time to carry-out the dynamic update and testing the safety shutdown paths (forced checking procedure).
Within the parameterized time, safe standstill must have been de-selected at least once. The monitoring time is
reset each time that SH is de-selected.
Dependency:
Refer to: A01699
p9761
SI password input / SI password input
VECTOR
Can be changed: C1, T
Data type: Unsigned32
P-Group: Safety Integrated
Min
0000 hex
Description:
Enters the Safety Integrated password.
Dependency:
Refer to: F01659
Note:
It is not permissible to change Safety Integrated parameter settings until the Safety Integrated password has been
entered.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: -
Units group: TIME_M3
Max
2000.00 [ms]
Data set: -
Units group: TIME_M3
Max
30000.00 [ms]
Data set: -
Units group: TIME_H
Max
9000.00 [h]
Data set: -
Units group: -
Max
FFFF FFFF hex
Parameters
Parameter list
Access level: 3
Function diagram: 2810
Unit selection: -
Factory setting
500.00 [ms]
Access level: 3
Function diagram: 2802
Unit selection: -
Factory setting
0.00 [ms]
Access level: 3
Function diagram: 2810
Unit selection: -
Factory setting
8.00 [h]
Access level: 3
Function diagram: 2800
Unit selection: -
Factory setting
0000 hex
1-349