Parameters
Parameter list
Bit field:
Bit
Signal name
00
Inverting BI: 1219[0]
01
Inverting BI: 1219[1]
02
Inverting BI: 1224[0]
03
Inverting BI: 1224[1]
05
Brake with feedback
p1276
Motor holding brake, standstill detection, bypass / Brk standst bypass
VECTOR (Extended
Can be changed: U, T
brk)
Data type: Floating Point
P-Group: Functions
Min
0.000 [s]
Description:
Sets the delay time for closing the brake at standstill.
After this time has expired, if the "close brake at standstill" or OFF1/OFF3 is present, the brake is closed and the
pulses are cancelled.
For p1276 = 300.000 s, the timer is de-activated - this means that the timer output is always zero.
p1277
Motor holding brake, braking threshold delay exceeded / Del thresh exceed.
VECTOR (Extended
Can be changed: U, T
brk)
Data type: Floating Point
P-Group: Functions
Min
0.000 [s]
Description:
Sets the delay time for the signal "braking threshold exceeded" (BO: r1229.6).
Dependency:
Refer to: p1220, p1221, r1229
p1279[0...3]
BI: Motor holding brake, OR/AND logic operation / MHB OR AND
VECTOR (Extended
Can be changed: T
brk)
Data type: Unsigned32
P-Group: Functions
Min
-
Description:
Sets the signal source for the OR/AND logic operation.
Dependency:
Refer to: r1229
Note:
[0]: OR logic operation, input 1 --> the result is displayed in r1229.10.
[1]: OR logic operation, input 2 --> the result is displayed in r1229.10.
[2]: AND logic operation, input 1 --> the result is displayed in r1229.11.
[3]: AND logic operation, input 2 --> the result is displayed in r1229.11.
p1280[0...n]
Vdc controller configuration (V/f) / Vdc_ctrl config
VECTOR
Can be changed: U, T
Data type: Integer16
P-Group: Functions
Min
0
Description:
Sets the configuration of the controller for the DC link voltage (Vdc controller) in the V/f operating mode.
Values:
0:
1:
2:
3:
1-168
Inhib Vdc ctrl
Enables Vdc_max controller
Enables Vdc_min controller (kinetic buffering)
Enables Vdc_min controller and Vdc_max controller
0 signal
No
No
No
No
No
Data set: -
Units group: TIME
Max
300.000 [s]
Data set: -
Units group: TIME
Max
300.000 [s]
Data set: -
Units group: -
Max
-
Data set: DDS
Units group: -
Max
3
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
1 signal
FP
Yes
2707
Yes
2707
Yes
2704
Yes
2704
Yes
2711
Access level: 2
Function diagram: 2704
Unit selection: -
Factory setting
300.000 [s]
Access level: 2
Function diagram: 2707
Unit selection: -
Factory setting
0.000 [s]
Access level: 2
Function diagram: 2707
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: 1690,
6320
Unit selection: -
Factory setting
1