Dependency:
The factory setting depends on p0500.
p0500 = 101 --> set to the maximum value
Otherwise --> set to the rated value
Refer to: p1531
Note:
For vector drives (refer to p0107):
The power limit is limited to 300% rated motor power.
p1531[0...n]
Power limit, regenerating / P_max gen
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
-10000.00 [kW]
Description:
Sets the regenerative power limit.
Dependency:
The factory setting depends on p0500.
p0500 = 101 --> set to the maximum value
Otherwise --> set to the rated value
Refer to: p1530
Note:
For vector drives (refer to p0107):
The power limit is limited to 300% rated motor power.
r1533
Current limit, torque-generating, total / Iq_max total
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Aeff]
Description:
Displays the maximum torque/force generating current as a result if all current limits.
r1536
Torque limit, torque-generating, maximum / Isq_max
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Control
Min
- [Aeff]
Description:
Displays the maximum limit for the torque-generating current component.
r1537
Torque limit, torque-generating, minimum / Isq_min
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Control
Min
- [Aeff]
Description:
Displays the minimum limit for the torque-generating current component.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: DDS
Units group: POWER_P3
Max
-0.01 [kW]
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Parameters
Parameter list
Access level: 2
Function diagram: 5640,
6640
Unit selection: -
Factory setting
-0.01 [kW]
Access level: 3
Function diagram: 5640,
5722, 6640
Factory setting
- [Aeff]
Access level: 4
Function diagram: 6640,
6710
Factory setting
- [Aeff]
Access level: 4
Function diagram: 6640,
6710
Factory setting
- [Aeff]
1-197