Siemens SINAMICS G List Manual page 359

Table of Contents

Advertisement

p9916
DRIVE-CLiQ data transfer error, shutdown threshold, slave / DLQ fault slave
CU
Can be changed: C1
Data type: Unsigned32
P-Group: Topology
Min
0000 hex
Description:
Only for internal Siemens service.
p9920[0...19]
Licensing, enter license key / Enter license key
CU
Can be changed: U, T
Data type: Unsigned8
P-Group: -
Min
0
Description:
Enters the license key for this drive unit.
Example of the license key:
EACZ-QBCA = 69 65 67 90 45 81 66 67 65 dec (ASCII characters)
Index 0 = license key character 1 (e.g. 69 dec)
Index 1 = license key character 2 (e.g. 65 dec)
...
Index 19 = license key character 20 (e.g. 0 dec)
Dependency:
Refer to: p9921
Refer to: A13000, A13001
Note:
When changing p9920[x] to the value 0, all of the following indices are also set to 0.
After entering the license key, the license key must be activated (p9921).
If the licensing is not adequate, then the following alarm is displayed together with LED:
- A13000 --> licensing not sufficient
- LED READY --> flashes green/red with 0.5 Hz
p9921
Licensing, activate license key / Act. license key
CU
Can be changed: U, T
Data type: Integer16
P-Group: -
Min
0
Description:
Activates the entered license key.
The following is executed when activating the license key.
- the checksum of the entered license key is checked.
- the entered license key is saved in the a non-volatile fashion on the CompactFlash Card.
- re-enter the license key.
Values:
0:
1:
Dependency:
Refer to: p9920
Refer to: A13000, A13001
Note:
When the license key has been activated, p9921 is automatically reset to 0.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
not active
Activate start license key
Data set: -
Units group: -
Max
0007 07FF hex
Data set: -
Units group: -
Max
255
Data set: -
Units group: -
Max
1
Parameters
Parameter list
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
0007 02FF hex
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
0
1-359