Siemens SINAMICS G List Manual page 567

Table of Contents

Advertisement

A07565 (F, N)
Drive: Encoder fault/error in PROFIdrive encoder interface 1
Reaction:
NONE
Acknowledge:
NONE
Cause:
An encoder error was signaled for encoder 1 via the PROFIdrive encoder interface (G1_ZSW.15).
Alarm value (r2124, decimal):
Error code from G1_XIST2, refer to the description regarding r0483.
Remedy:
Acknowledge the encoder error using the encoder control word (G1_STW.15 = 1).
Reaction upon F:
NONE (OFF1, OFF2, OFF3)
Acknowledge
IMMEDIATELY
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
A07566 (F, N)
Drive: Encoder fault/error in PROFIdrive encoder interface 2
Reaction:
NONE
Acknowledge:
NONE
Cause:
An encoder error was signaled for encoder 2 via the PROFIdrive encoder interface (G2_ZSW.15).
Alarm value (r2124, decimal):
Error code from G2_XIST2, refer to the description regarding r0483.
Remedy:
Acknowledge the encoder error using the encoder control word (G2_STW.15 = 1).
Reaction upon F:
NONE (OFF1, OFF2, OFF3)
Acknowledge
IMMEDIATELY
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
A07567 (F, N)
Drive: Encoder fault/error in PROFIdrive encoder interface 3
Reaction:
NONE
Acknowledge:
NONE
Cause:
An encoder error was signaled for encoder 3 via the PROFIdrive encoder interface (G3_ZSW.15).
Alarm value (r2124, decimal):
Error code from G3_XIST2, refer to the description regarding r0483.
Remedy:
Acknowledge the encoder error using the encoder control word (G3_STW.15 = 1).
Reaction upon F:
NONE (OFF1, OFF2, OFF3)
Acknowledge
IMMEDIATELY
upon F:
Reaction upon N:
NONE
Acknowledge
NONE
upon N:
F07570
Drive encoder: Existing speed encoder not parameterized
Reaction:
NONE
Acknowledge:
IMMEDIATELY (power on)
Cause:
In spite of the fact that a speed encoder exists (refer to topology r0098) this was not parameterized.
Fault value (r0949, decimal):
Encoder data set index of the incorrect parameterization of p0400.
See also: p0141, p0187, p0188, p0189, p0400
Remedy:
Select the speed encoder in p0400.
See also: p0400
F07575
Drive: Motor encoder not ready
Reaction:
OFF2 (NONE)
Acknowledge:
IMMEDIATELY
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Faults and Alarms
List of faults and alarms
3-567

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents