Siemens SINAMICS G List Manual page 540

Table of Contents

Advertisement

Faults and Alarms
List of faults and alarms
F01649
SI CU: Internal software error
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (power on)
Cause:
An internal error in the Safety Integrated software on the control unit has occurred.
Note:
This fault results in a STOP A that cannot be acknowledged.
Fault value (r0949, hexadecimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry-out a POWER ON (power off/on) for all components.
- re-commission the Safety Integrated function and carry-out a POWER ON.
- upgrade the control unit software.
- contact the Hotline.
- replace the control unit.
Note:
CU: Control unit
SI: Safety Integrated
F01650
SI CU: Acceptance test required
Reaction:
OFF2
Acknowledge:
IMMEDIATELY (power on)
Cause:
The Safety Integrated function on the control unit requires an acceptance test.
Note:
This fault results in a STOP A.
Fault value (r0949, decimal):
130: No safety parameters available for the motor module.
1000: Reference and actual checksum on the control unit are not identical (run-up).
- at least one checksum-checked piece of data is defective.
2000: Reference and actual checksum on the control unit are not identical (commissioning mode).
- reference checksum incorrectly entered into the control unit (p9799 not equal to r9798).
2001: Reference and actual checksum on the motor module are not identical (commissioning mode).
- reference checksum incorrectly entered into the motor module (p9899 not equal to r9898).
2002: Enable of safety-related functions between the control unit and motor module differ (p9601 not equal to
p9801).
2003: Acceptance test is required as a safety parameter has been changed.
2010: Safe brake control is enabled differently the control unit and motor module (p9602 not equal to p9802).
2020: Error when saving the safety parameters for the motor module.
9999: Subsequent response of another safety-related fault that occurred at run-up that requires an acceptance test.
Remedy:
Re fault value = 130:
- carry-out safety commissioning routine.
Re fault value = 1000:
- again carry-out safety commissioning routine.
- replace the CompactFlash Card.
Re fault value = 2000:
- check the safety parameters in the control unit and adapt the reference checksum (p9799).
Re fault value = 2001:
- check the safety parameters in the motor module and adapt the reference checksum (p9899).
Re fault value = 2002:
- enable the safety-related functions on the control unit and check on the motor module (p9601 = p9801).
Re fault value = 2003:
- carry-out an acceptance test.
Re fault value = 2010:
- enable the safe brake control in the control unit and check on the motor module (p9602 = p9802).
Re fault value = 2020:
- again carry-out safety commissioning routine.
- replace the CompactFlash Card.
Re fault value = 9999:
- carry-out diagnostics for the other safety-related fault that is present.
Note:
CU: Control unit
SI: Safety Integrated
See also: p9799, p9899