r0094
Transformation angle / Transformat_angle
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [°]
Description:
Displays the transformation angle.
Note:
The transformation angle corresponds to the electrical commutation angle.
p0097
Select drive object type / Select DO type
CU
Can be changed: C1
Data type: Integer16
P-Group: Topology
Min
0
Description:
Executes an automatic device configuration.
In so doing, p0099, p0107 and p0108 are appropriately set.
Values:
0:
1:
2:
3:
12:
Dependency:
Refer to: r0098, p0099
Refer to: A01330
Note:
For p0097 = 0, p0099 is automatically set to the factor setting.
The setting p0097 = 1 is not possible for chassis-type power modules as well as for SINAMICS G or SINAMICS
GM.
The setting p0097 = 12 is not possible for booksize power modules.
r0098[0...5]
Actual device topology / Device_act topo
CU
Can be changed: -
Data type: Unsigned32
P-Group: Topology
Min
-
Description:
Displays the automatically detected actual device topology in coded form.
Index:
[0] = DRIVE-CLiQ socket X100
[1] = DRIVE-CLiQ socket X101
[2] = DRIVE-CLiQ socket X102
[3] = DRIVE-CLiQ socket X103
[4] = DRIVE-CLiQ socket X104
[5] = DRIVE-CLiQ socket X105
Dependency:
Refer to: p0097, p0099
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
No selection
Drive object type SERVO
Drive object type VECTOR
Drive object type VECTORMV
Drive object type VECTOR parallel circuit
Data set: -
Units group: ANGLE
Max
- [°]
Data set: -
Units group: -
Max
12
Data set: -
Units group: -
Max
-
Parameters
Parameter list
Access level: 3
Function diagram: 1580,
4710, 6714, 6730
Unit selection: -
Factory setting
- [°]
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 1
Function diagram: -
Unit selection: -
Factory setting
-