Siemens SINAMICS G List Manual page 195

Table of Contents

Advertisement

Note:
For vector drives (refer to p0107):
The torque limit is limited to 400% of the rated motor torque.
p1522[0...n]
CI: Torque limit, upper/motoring / M_max upper/mot
VECTOR (n/M)
Can be changed: T
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Sets the signal source for the upper or torque/force limit when motoring.
Dependency:
p1400 bit 4 = 0: top / bottom
p1400 bit 4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1523
p1523[0...n]
CI: Torque limit, lower/regenerative / M_max lower/regen
VECTOR (n/M)
Can be changed: T
Data type: Unsigned32
P-Group: Control
Min
-
Description:
Sets the signal source for the lower or torque/force limit when regenerating.
Dependency:
p1400 bit 4 = 0: top / bottom
p1400 bit 4 = 1: motoring / regenerating
Refer to: p1520, p1521, p1522
p1524[0...n]
CO: Torque limit, upper/motoring, scaling / M_max up/mot scal
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
-2000.0 [%]
Description:
Sets the scaling for the upper torque limit or the motoring torque limit when motoring.
Dependency:
p1400 bit 4 = 0: top / bottom
p1400 bit 4 = 1: motoring / regenerating
Note:
This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
p1525[0...n]
CO: Torque limit, lower/regenerating scaling / M_max low/gen scal
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
-2000.0 [%]
Description:
Sets the scaling for the lower torque limit or the torque limit when regenerating.
Dependency:
p1400 bit 4 = 0: top / bottom
p1400 bit 4 = 1: motoring / regenerating
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Data set: CDS
Units group: -
Max
-
Data set: CDS
Units group: -
Max
-
Data set: DDS
Units group: PERCENT
Max
2000.0 [%]
Data set: DDS
Units group: PERCENT
Max
2000.0 [%]
Parameters
Parameter list
Access level: 3
Function diagram: 1610,
5620, 5630, 6630
Unit selection: -
Factory setting
1520[0]
Access level: 3
Function diagram: 1610,
5620, 5630, 6630
Unit selection: -
Factory setting
1521[0]
Access level: 3
Function diagram: 5620,
5630, 6630
Unit selection: -
Factory setting
100.0 [%]
Access level: 3
Function diagram: 5620,
5630, 6630
Unit selection: -
Factory setting
100.0 [%]
1-195