Siemens SINAMICS G List Manual page 100

Table of Contents

Advertisement

Parameters
Parameter list
p0602
Power module number, temperature sensor for parallel circuit configuration / Mot
temp_PM number
VECTOR (Parallel)
Can be changed: C2, U, T
Data type: Unsigned16
P-Group: Motor
Min
0
Description:
Sets the power module number to which the temperature sensor is connected. The value corresponds to the power
module data set number (Power Data Set, PDS) of the power module. The number power module data sets is
defined in parameter p0120.
p0603
CI: Motor temperature / Mot temperature
VECTOR
Can be changed: C2, T
Data type: Unsigned32
P-Group: Motor
Min
-
Description:
Sets the signal source to evaluate the motor temperature via a BICO interconnection.
Dependency:
Refer to: p0600
Note:
KTY temperature sensor: Valid temperature range -48 °C ... 248 °C.
PTC temperature sensor:
For the -50 °C, the following applies: Motor temperature < nominal response temperature of the PTC.
For the 250 °C, the following applies: Motor temperature >= nominal response temperature of the PTC.
Note:
When using a terminal module 31 (TM31), the following applies:
- the sensor type used is set using p4100.
- the temperature signal is interconnected using CO: r4105.
p0604[0...n]
Motor overtemperature alarm threshold / Mot TempAlrmThresh
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
0.0 [°C]
Description:
Sets the alarm threshold for monitoring the motor temperature.
Note:
The parameter is automatically preset for motors from the motor list (p0301).
p0605[0...n]
Motor overtemperature fault threshold / MotTempFaultThresh
VECTOR
Can be changed: C2, U, T
Data type: Floating Point
P-Group: Motor
Min
0.0 [°C]
Description:
Sets the fault threshold to monitor the motor temperature.
Note:
The parameter is automatically preset for motors from the motor list (p0301).
1-100
Data set: -
Units group: -
Max
10
Data set: -
Units group: -
Max
-
Data set: MDS
Units group: TEMPERATURE
Max
200.0 [°C]
Data set: MDS
Units group: TEMPERATURE
Max
200.0 [°C]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: 8016
Unit selection: -
Factory setting
0
Access level: 2
Function diagram: 8016
Unit selection: -
Factory setting
120.0 [°C]
Access level: 2
Function diagram: 8016
Unit selection: -
Factory setting
155.0 [°C]