Parameters
Parameter list
p1082[0...n]
Maximum speed / Maximum speed
VECTOR
Can be changed: C2, T
Data type: Floating Point
P-Group: Setpoints
Min
0.000 [1/min]
Description:
Sets the highest possible speed/velocity.
The value in p1082 is calculated, during the commissioning phase, dependent on the motor and drive unit and can
only be equal to or less than the value in p0322 (maximum motor speed).
Dependency:
If a sinusoidal filter (p0230 = 3) is parameterized as output filter, then the maximum speed is limited corresponding
to the maximum permissible filter output frequency (refer to the filter data sheet).
Refer to: p0115, p0230, r0313, p0322, r0336
Note:
The parameter applies for both motor directions.
p1083[0...n]
CO: Speed limit in positive direction of rotation / n_limit pos
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
0.000 [1/min]
Description:
Sets the maximum speed/velocity for the positive direction.
r1084
Speed limit positive effective / n_limit pos eff
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Setpoints
Min
- [1/min]
Description:
Displays the effective positive speed/velocity limit.
p1085[0...n]
CI: Speed limit in positive direction of rotation / n_limit pos
VECTOR
Can be changed: T
Data type: Unsigned32
P-Group: Setpoints
Min
-
Description:
Sets the signal source for the speed/velocity limit of the positive direction.
p1086[0...n]
CO: Speed limit negative direction of rotation / n_limit neg
VECTOR
Can be changed: U, T
Data type: Floating Point
P-Group: Setpoints
Min
-210000.000 [1/min]
Description:
Sets the speed/velocity limit for the negative direction (of rotation).
1-146
Data set: DDS
Units group: SPEED_ROT
Max
210000.000 [1/min]
Data set: DDS
Units group: SPEED_ROT
Max
210000.000 [1/min]
Data set: -
Units group: SPEED_ROT
Max
- [1/min]
Data set: CDS
Units group: -
Max
-
Data set: DDS
Units group: SPEED_ROT
Max
0.000 [1/min]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 1
Function diagram: 3050,
3060, 3070, 5300
Unit selection: -
Factory setting
1500.000 [1/min]
Access level: 2
Function diagram: 3050
Unit selection: -
Factory setting
210000.000 [1/min]
Access level: 3
Function diagram: 3050,
5030, 5210, 6640, 8010
Unit selection: -
Factory setting
- [1/min]
Access level: 3
Function diagram: 3050
Unit selection: -
Factory setting
1083[0]
Access level: 2
Function diagram: 3050
Unit selection: -
Factory setting
-210000.000 [1/min]