r1979
BO: Speed controller optimization status / n_opt status
VECTOR (n/M)
Can be changed: -
Data type: Unsigned16
P-Group: Motor identification
Min
-
Description:
Displays the status to check and monitor the states of speed controller optimization.
Bit field:
Bit
Signal name
00
Speed controller optimization activated
01
Speed controller optimization completed
02
Speed controller optimization interrupted
04
Enc test active
05
Saturation char. identification active
06
Moment of inertia identification active
07
Recalc. speed controller parameters active
08
Speed controller vibration test active
09
Magnetizing induction adapt. active
10
Operation with encoder after sensorless
operation
p1980[0...n]
Rotor position identification technique / RotPosID technique
VECTOR
Can be changed: U, T
Data type: Integer16
P-Group: Motor identification
Min
10
Description:
Sets the rotor position identification technique.
Values:
10:
r1984
Rotor position identification, angular difference / RotPosID ang diff
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Motor identification
Min
- [°]
Description:
Displays the electrical angular difference: Determined angular rotor position identification minus the encoder angle.
p1990
Encoder adjustment selection / Encod adjust sel
VECTOR
Can be changed: T
Data type: Integer16
P-Group: Motor identification
Min
0
Description:
Activates the automatic encoder adjustment
The adjustment value determined is saved in p0431.
Values:
0:
1:
Dependency:
Refer to: p0431
Note:
p1990 is automatically set to 0 after the encoder has been adjusted.
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Current is being impressed, the motor aligns itself
Encoder adjustment de-activated
Enc adjust. active
Data set: -
Units group: -
Max
-
0 signal
No
No
No
No
No
No
No
No
No
No
Data set: MDS
Units group: -
Max
10
Data set: -
Units group: ANGLE
Max
- [°]
Data set: -
Units group: -
Max
1
Parameters
Parameter list
Access level: 4
Function diagram: -
Unit selection: -
Factory setting
-
1 signal
FP
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
10
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
- [°]
Access level: 2
Function diagram: -
Unit selection: -
Factory setting
0
1-231

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents