Parameters
Parameter list
Bit field:
Bit
Signal name
00
DC/AC device
01
RFI filter available
02
Active line module available
04
Basic line module available with thyristor
bridge
05
Basic line module available with diode
bridge
12
Safe brake control (SBC) supported
Note:
For parallel circuit configurations, the parameter index is assigned to a power module.
p0205
Power module application / PM application
VECTOR
Can be changed: C2
Data type: Integer16
P-Group: Drive converter
Min
0
Description:
The overload conditions of the load duty cycles are valid under the prerequisite that before and after the overload
condition, the drive converter is operated with its base load current - this is based on a load duty cycle of 300 s.
The following applies for chassis drive units:
The base load current for a slight overload is based on a duty cycle of 110% for 60 s or 150% for 10 s.
The base load current for a high overload is based on a duty cycle of 150% for 60 s or 160% for 10 s.
The following applies for booksize drive units:
Only the setting p0205 = 0 can be selected. In this case, for the base load current, there is a load duty cycle of
150% for 60 s or 176% for 30 s.
Values:
0:
1:
6:
7:
Note:
When the parameter is changed, all of the motor parameters and the control type are pre-assigned according to the
selected application. The parameter has not influence when calculating the thermal overload.
p0205 can only be changed to the settings that are saved in the power module EEPROM.
Its value is not reset when factory values are restored (see p0010 = 30, p0970).
r0206[0...4]
Rated power module power / PM P_rated
VECTOR
Can be changed: -
Data type: Floating Point
P-Group: Drive converter
Min
- [kW]
Description:
Displays the rated power module power for various load duty cycles.
Index:
[0] = Rating plate
[1] = Load duty cycle with high overload condition
[2] = Load duty cycle with slight overload condition
[3] = S1 load duty cycle
[4] = S6 load duty cycle
Dependency:
The value is displayed in [kW] or [hp].
Refer to: p0100, p0205
1-58
Load duty cycle with high overload condition for vector drives
Load duty cycle with slight overload condition for vector drives
S1 duty cycle for servo drives (feed drive)
S6 duty cycle for servo drives (spindle drive)
0 signal
AC/AC device
No
No
No
No
Yes
Data set: -
Units group: -
Max
7
Data set: -
Units group: POWER_P3
Max
- [kW]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
1 signal
FP
DC/AC device
-
Yes
-
Yes
-
Yes
-
Yes
-
No
-
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
6
Access level: 2
Function diagram: -
Unit selection: p0100
Factory setting
- [kW]