Parameters
Parameter list
p1611[0...n]
Supplementary accelerating torque (SLVC) / M_suppl_accel
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.0 [%]
Description:
Enters the dynamic torque setpoint for the low-speed range for sensorless vector control (SLVC). This parameter is
entered as a percentage referred to the rated motor torque (r0333).
Note:
When accelerating and braking p1611 is added to p1610 and the resulting total torque is converted into an appro-
priate current setpoint and controlled.
For pure accelerating torques, it is always favorable to use the torque pre-control of the speed controller (p1496).
p1616[0...n]
Current setpoint smoothing time / I_set T_smooth
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
4 [ms]
Description:
Sets the smoothing time for the current setpoint.
The current setpoint is generated from p1610 and p1611.
Note:
This parameter is only effective in the range where current is impressed for sensorless vector control.
r1623
Field-generating current setpoint (steady-state) / Id_set stationary
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Aeff]
Description:
Displays the steady-state field generating current setpoint (Id_set).
r1624
Field-generating current setpoint, total / Id_set total
VECTOR (n/M)
Can be changed: -
Data type: Floating Point
P-Group: Displays, signals
Min
- [Aeff]
Description:
Displays the limited field-generating current setpoint (Id_set).
This value comprises the steady-state field-generating current setpoint r1623 and a dynamic component that is only
set when changes are made to the flux setpoint.
p1654[0...n]
Current setpoint torque-generating smoothing time / Isq_set T_smooth
VECTOR (n/M)
Can be changed: U, T
Data type: Floating Point
P-Group: Control
Min
0.1 [ms]
Description:
Sets the smoothing time constant for the setpoint of the torque-generating current components.
Note:
The smoothing time does not become effective until the field-weakening range is reached.
1-202
Data set: DDS
Units group: PERCENT
Max
200.0 [%]
Data set: DDS
Units group: TIME_M3
Max
10000 [ms]
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: -
Units group: CURRENT_AC_EFF Unit selection: -
Max
- [Aeff]
Data set: DDS
Units group: TIME_M3
Max
20.0 [ms]
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 2
Function diagram: 6722
Unit selection: -
Factory setting
0.0 [%]
Access level: 3
Function diagram: 6722
Unit selection: -
Factory setting
40 [ms]
Access level: 4
Function diagram: 6723
Factory setting
- [Aeff]
Access level: 4
Function diagram: 6640,
6723, 6724
Factory setting
- [Aeff]
Access level: 4
Function diagram: 6710
Unit selection: -
Factory setting
4.8 [ms]