Trigger signal p2128[6]
07
Trigger signal p2128[7]
08
Trigger signal p2128[8]
09
Trigger signal p2128[9]
10
Trigger signal p2128[10]
11
Trigger signal p2128[11]
12
Trigger signal p2128[12]
13
Trigger signal p2128[13]
14
Trigger signal p2128[14]
15
Trigger signal p2128[15]
Dependency:
If one of the faults or alarms selected in p2128[n] occurs, then the particular bit of this binector output is set.
Refer to: p2128
Note:
CO: r2129 = 0 --> None of the selected messages has occurred.
CO: r2129 > 0 --> At least one of the selected messages has occurred.
r2130[0...63]
Fault time received in days / t_fault recv days
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the system runtime in days when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2133, r2136
r2131
CO: Actual fault code / Actual fault code
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the code of the oldest active fault.
Note:
0: No fault present.
r2132
CO: Actual alarm code / Actual alarm code
All objects
Can be changed: -
Data type: Unsigned16
P-Group: Messages
Min
-
Description:
Displays the code of the last alarm that occurred.
Note:
0: No alarm present.
r2133[0...63]
Fault value for float values / Fault val float
All objects
Can be changed: -
Data type: Floating Point
P-Group: Messages
Min
-
Description:
Displays additional information about the fault that occurred for float values.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2136
Note:
Displays additional information about the safety fault that has occurred (for float values)
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Data set: -
Units group: -
Max
-
Parameters
Parameter list
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
On
-
Access level: 3
Function diagram: 8060
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: 8060
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: 8065
Unit selection: -
Factory setting
-
Access level: 3
Function diagram: 8060
Unit selection: -
Factory setting
-
1-259