Parameters
Parameter list
Notice:
It is not possible to re-parameterize the fault response to a fault in the following cases:
- if there is no existing fault number.
- the message type is not "fault" (F).
- when a fault is present.
p2101[0...19]
Setting the fault response / Fault response
All objects
Can be changed: U, T
Data type: Integer16
P-Group: Messages
Min
0
Description:
Sets the fault response for the selected fault.
Values:
0:
1:
2:
3:
4:
5:
6:
7:
Dependency:
The fault is selected and the required response is set under the same index.
Refer to: p2100
Notice:
It is not possible to re-parameterize the response to a specific fault for faults that are already present (queued).
Note:
OFF1:
Braking along the ramp-function generator down ramp followed by a pulse inhibit.
OFF2:
Internal/external pulse inhibit.
OFF3:
Braking along the OFF3 down ramp followed by a pulse inhibit.
STOP2:
n_set = 0
The fault response can only be changed for faults with the appropriate identification.
Example:
F12345 and fault response = NONE (OFF1, OFF2) --> The NONE fault response can be changed to either OFF1 or
OFF2.
p2103
BI: 1. Acknowledge faults / 1. Acknowledge
CU, TB30, TM31
Can be changed: U, T
Data type: Unsigned32
P-Group: Messages
Min
-
Description:
Sets the first signal source to acknowledge faults.
Note:
A fault acknowledgment is triggered with a 0/1 signal.
1-250
NONE
OFF1
OFF2
OFF3
STOP1 (being developed)
STOP2
DCBRAKE (being developed)
ENCODER (p0491)
Data set: -
Units group: -
Max
7
Data set: -
Units group: -
Max
-
 Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Access level: 3
Function diagram: 1750,
8075
Unit selection: -
Factory setting
0
Access level: 3
Function diagram: -
Unit selection: -
Factory setting
0