Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
● Tests that are offered as standard Note If the scope of testing and inspection cannot fulfill all customer requirements, please consult your Siemens sales advisor at head office. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
5. Preparation of test documentation for the customer. The test documentation is created before or after the customer leaves depending on the scope of testing and the time schedule. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
Page 10
PD LD scope of supply. This also applies to components ordered from other Siemens' Groups. The technical data for these components is required at the latest eight weeks before the start of the acceptance test, e.g.: ●...
General scope of services 2.1 Routine test Routine test During production, the drive is subject to an internal routine test. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
Siemens directives within the scope of quality assurance. The function tests are performed and documented in the Siemens test field by internal test field personnel. For the function test, the drive is in the test mode with restricted monitoring functions.
3.2 certificate. See also Insulation test (Page 30) The insulation test is performed on a separate acceptance day prior to the function test. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
● Additional interfaces The test is confirmed in a 3.1 certificate – or in the case that the customer has ordered the acceptance test, in a 3.2 certificate. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
Page 16
General scope of services 2.5 Interface test SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
Tests The tests that have been expressly ordered for the drive with serial number 12345670001001 are listed in the following. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
The test together with the customer – or his representative – is carried out with the drive installed and labeled. The results of all of the tests are documented in the acceptance report. The SINAMICS SL150 drive consists of the following components: ● Power section ●...
Cable installation Fundamentals Visual and mechanical checks are made to ensure that cables and conductors have been installed correctly and are connected correctly according to the circuit diagram. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
Test procedure 1. The customer selects circuit breakers by random sampling. 2. The circuit breaker settings are visually checked against what is specified in the circuit diagram. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
3.1.9 Clamping pressure on the power semiconductor stack in the power section Fundamentals The clamping pressure on the power semiconductor stack is tested with a preclamping gage. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
– Are restrictor tubes provided at the intended locations? Result The test is passed if the hoses and pipes have been correctly installed and match the diagrams. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
3. The value of the synchronization voltage is read off from the test station computer and compared with the applied voltage. Result The test is passed if the voltage values match. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
The test reveals whether a message is displayed on the test station computer when a ground fault occurs. Test procedure 1. The auxiliary voltage is present. 2. The signal cable for signaling the ground fault is interrupted. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
This simulates a failure of actual value acquisition. The drive switches itself off. A fault is displayed on the test station computer. Result The test is passed if the drive responds as described. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
3. The output current and output voltage are measured at the output of the power semiconductor module. Result The test is passed if the defined values are measured at the output of the power semiconductor module. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
The progression of the current zero signal is displayed on the test station computer. Result The test is passed if the current gaps are symmetrically distributed over the current zero signal. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
5. The pressure drop is calculated from measured values: Δp = p Result The test is passed if the differential pressure is ≤ 0.4 bar and no leaks have occurred in the cooling system. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
The reference differential pressure is calculated from the measured values of the cooling unit: Δp = p Result The test is passed if the differential pressure Δp = 2.2 ±0.2 bar. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
5. The test is repeated with 80% test voltage. Result The test is passed if the test instrument is not switched off (tripped) during the test as a result of flashover. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
4. The circuits are tested with respect to one another and with respect to the PE protective conductor at the electrical cabinet. Result The test is passed if the insulation resistances lie within the tolerance specified by the standard. SINAMICS SL150 6SL3865 F03 F70 F98 F79 F76 Reference Manual Rev.201902141427 SL150 wassergekühlt...
Page 36
8888888888 000088 01 EN 01 Further Information www.siemens.com/drives Siemens AG Process Industries and Drives Postfach 48 48 90026 NÜRNBERG GERMANY *888888888800008801EN01* 888888888800008801EN01...
Page 37
Process Industries and Drives Department PD LD P MF-NMA EN Siemens AG, PD LD P MF-NMA EN, Postfach 47 43, 90025 Nürnberg Tel. +49 (911) 433-6422 +49 (911) 433-6921 Email motoren.doku.aud@internal.siemens.co Our ref. 8888888888000088 Date 14.02.2019 Documentation for 6SL3865 Your order no. - 000010...