Maintenance for CSI systems
NOTE:
Before placing an outgoing ISDN-PRI test call, verify that the FAC on the
System Features screen has been administered, and the Far End Test Line
No and TestCall Bearer Capability Class (BCC) fields are administered on
the Trunk Group Administration screen. If the ISDN-PRI trunk service type is
"cbc" (call by call), then the Testcall Service field on Trunk Group
Administration screen be administered.
To initiate an outgoing ISDN-PRI test call in the asynchronous method, type:
test isdn-testcall <grp>/<mbr> [minutes]
This command enables you to specify a specific the trunk on which to originate
the ISDN-PRI test call.
NOTE:
The optional qualifier can also be used that specifies in minutes the duration
of the test call. If no duration is specified, the default duration is used which
is 8.4 or 9.6 seconds. The qualifier "minutes" accepts the numeric values
one through 120 (that is, two hours = 120 minutes).
Screen 17
shows a typical response to the test isdn-testcall command:
test isdn-testcall
Port
Maintenance Name
1B1501
ISDN-TRK
Screen 17. Typical Response to Test ISDN-Testcall Command
94
Issue 5 October 2002
Test Number
Test Result
258
PASS
Error Code
555-233-119