016-378 Cont Hdd Filesystem Fail-G Rap; 016-379 Cont Hdd Filesystem Fail-H Rap - Xerox workcentre 5335 series Service Manual

Table of Contents

Advertisement

016-378 Cont HDD FileSystem Fail-G RAP

BSD-ON:
BSD 16.1 - ESS
Boot Diag detected a logic error with HDD (Partition G).
Procedure
Perform the following:
1.
Power OFF then ON.
2.
Initialize the HDD
Initialize Hard
Initial Issue
WorkCentre 5335 Family Service Documentation
Disk.
BUS Updated 12/2011

016-379 Cont HDD FileSystem Fail-H RAP

BSD-ON:
BSD 16.1 - ESS
Boot Diag detected a logic error with HDD (Partition H).
Procedure
Perform the following:
1.
Power OFF then ON.
2.
Initialize the HDD
Initialize Hard
07/2011
2-173
Disk.
Status Indicator RAPs
016-378, 016-379

Advertisement

Table of Contents
loading

This manual is also suitable for:

Workcentre 5335 series

Table of Contents