016-351 ESS EEPROM DIAG Failure 2 RAP

BSD-ON:
BSD 16.1 - ESS
Read/Write/Verify error for the ESS EEPROM.
Initial Actions
Power Off/On.
Procedure
1.
Check connections between the following components:
ESS EEPROM and ESS PWB (check for bent pins etc.)
2.
Check the sw version of the controller sw - update if required
3.
If problem persists replace ESS PWB.
Initial Issue
WorkCentre 5335 Family Service Documentation
(PL
35.2).
PL
35.3.
BUS Updated 12/2011

016-360 Cont UI Fail-1 RAP

BSD-ON:
BSD 16.1 - ESS
Cont UI Diagnostic Fail-1. An error occurred during W/R/V test of PCI Config interval.
Procedure
Turn the power OFF then ON. If the problem persists, perform the following:
1.
Remove and re-install the UI I/F PWB
2.
Check the sw version of the controller sw - update if required
3.
If problem persists replace ESS PWB.
4.
Replace the UI I/F PWB
(PL
5.
Replace the ESS PWB
(PL
07/2011
2-165
(PL
1.7).
PL
35.3.
1.7).
35.2).
Status Indicator RAPs
016-351, 016-360